Back to Search Start Over

Robotic valvuloplastic esophagogastrostomy using double flap technique following proximal gastrectomy: technical aspects and short-term outcomes.

Authors :
Shibasaki S
Suda K
Nakauchi M
Kikuchi K
Kadoya S
Ishida Y
Inaba K
Uyama I
Source :
Surgical endoscopy [Surg Endosc] 2017 Oct; Vol. 31 (10), pp. 4283-4297. Date of Electronic Publication: 2017 Mar 31.
Publication Year :
2017

Abstract

Background: Valvuloplastic esophagogastrostomy by double flap technique (VEG-DFT) is a promising procedure to prevent reflux after proximal gastrectomy (PG), and is achieved by the burial of the abdominal esophagus into the gastric submucosa; however, laparoscopic VEG-DFT is technically demanding due to complicated suturing and ligation maneuvers. The present study was designed to determine the feasibility and safety of robotic VEG-DFT.<br />Methods: After robotic PG, seromuscular flaps were extracorporeally created at the anterior wall of the remnant stomach through a small umbilical incision. Then, using a robot, the posterior wall of the esophagus was fixed to the cranial end of the mucosal window, and layer-to-layer sutures were placed between the anterior aspects of esophagus and the remnant stomach. Finally, the anastomosis was covered by seromuscular flaps. Short-term outcomes of 12 consecutive patients who underwent VEG-DFT between January 2014 and December 2015 were assessed.<br />Results: Operations were successfully completed using robotic assistance in all patients. Median operative, surgeon console, and anastomosis times were 406 (324-613 min), 267 (214-483), and 104 (76-186) min, respectively, and median estimated blood loss was 31 (5-130) ml. The first six cases were required to reach a learning plateau. Both mortality and morbidity rates within 30 days after surgery were 0%. Postoperative hospital stay was 10 (9-30) days. No postoperative reflux esophagitis was observed, whereas anastomotic stenosis, which required endoscopic balloon dilation, developed in three patients (25%) in postoperative month 2. There was a significant association between the total number of stitches used for VEG-DFT and anastomotic stenosis (p < 0.001).<br />Conclusions: Robotic assistance may be useful for VEG-DFT with a short learning curve. Attention is required to prevent postoperative anastomotic stenosis possibly caused by an excessive number of stitches for esophagogastrostomy.

Details

Language :
English
ISSN :
1432-2218
Volume :
31
Issue :
10
Database :
MEDLINE
Journal :
Surgical endoscopy
Publication Type :
Academic Journal
Accession number :
28364148
Full Text :
https://doi.org/10.1007/s00464-017-5489-x