Back to Search
Start Over
A Study on the Effects of Release Area on the Quality Factor of Contour-Mode Resonators by Laser Doppler Vibrometry.
- Source :
-
IEEE transactions on ultrasonics, ferroelectrics, and frequency control [IEEE Trans Ultrason Ferroelectr Freq Control] 2017 May; Vol. 64 (5), pp. 898-904. Date of Electronic Publication: 2017 Mar 15. - Publication Year :
- 2017
-
Abstract
- Through the use of a laser Doppler vibrometer, it is shown that a 31% variation in quality factor can occur due to the effect of undercutting of the device layers outside of the anchors of a 220-MHz aluminum nitride contour-mode resonator. This undercutting is a result of the isotropic etch process used to release the device from the substrate. This paper shows that the variation in Q is a function of the release distance, L , between the active region of the resonator and the edge of this released region. This paper also determined a design modification that eliminated this issue and achieved a Q of 3048, which is independent of L .
Details
- Language :
- English
- ISSN :
- 1525-8955
- Volume :
- 64
- Issue :
- 5
- Database :
- MEDLINE
- Journal :
- IEEE transactions on ultrasonics, ferroelectrics, and frequency control
- Publication Type :
- Academic Journal
- Accession number :
- 28320655
- Full Text :
- https://doi.org/10.1109/TUFFC.2017.2681109