Back to Search
Start Over
A New Handheld Device for the Detection of Falsified Medicines: Demonstration on Falsified Artemisinin-Based Therapies from the Field.
- Source :
-
The American journal of tropical medicine and hygiene [Am J Trop Med Hyg] 2017 May; Vol. 96 (5), pp. 1117-1123. Date of Electronic Publication: 2017 May 13. - Publication Year :
- 2017
-
Abstract
- AbstractPoor-quality medicines are a major problem for health-care systems in resource-poor settings as identifying falsified medicines requires a complex laboratory infrastructure such as a Medicines Quality Control Laboratory. We report here an evaluation of a low-cost, handheld near-infrared spectrometer (NIRS) device by analyzing a library of artemisinin-based combination therapy (ACT) medicines to determine its usefulness as a drug-screening tool. The "SCiO" research prototype device was used to collect NIR spectra of a library of ACT and artesunate monotherapy medicine samples previously collected in Bioko Island and Equatorial Guinea and Kintampo, Ghana. The quality of these samples had been categorized as falsified, substandard, and quality assured based on the amount of stated active pharmaceutical ingredients detected using high-performance liquid chromatography photodiode array. Numerical analyses were performed on the NIR spectra to assess the usefulness of NIR to identify falsified and substandard medicines. The NIRS device was successful at detecting falsified medicines in all cases where the library contained both quality assured and falsified medicines of the same stated brand of medicines. The NIRS device was successful at identifying substandard amounts of artesunate but not amodiaquine in the ACT samples ( N = 15) of artesunate-amodiaquine. This work reveals that this low-cost, portable NIRS device is promising for screening ACTs for falsified samples and could enable widespread drug screening at all points of the health system.
- Subjects :
- Artesunate
Chromatography, High Pressure Liquid
Drug Combinations
Drug Contamination prevention & control
Equatorial Guinea
Ghana
Humans
Mobile Applications
Quality Control
Sensitivity and Specificity
Spectrophotometry, Infrared instrumentation
Spectrophotometry, Infrared methods
Amodiaquine analysis
Antimalarials analysis
Artemisinins analysis
Computers, Handheld
Counterfeit Drugs analysis
Subjects
Details
- Language :
- English
- ISSN :
- 1476-1645
- Volume :
- 96
- Issue :
- 5
- Database :
- MEDLINE
- Journal :
- The American journal of tropical medicine and hygiene
- Publication Type :
- Academic Journal
- Accession number :
- 28219992
- Full Text :
- https://doi.org/10.4269/ajtmh.16-0904