Back to Search
Start Over
Biomechanical properties of bovine tendon xenografts treated with a modern processing method.
- Source :
-
Journal of biomechanics [J Biomech] 2017 Feb 28; Vol. 53, pp. 144-147. Date of Electronic Publication: 2017 Jan 13. - Publication Year :
- 2017
-
Abstract
- Xenograft tendons have been used in few human studies, with variable results. With the advent of novel tissue processing techniques, which may mitigate against an immune-mediated rejection response without adversely affecting mechanical properties, there may now be a clinical role for xenograft tendons, particularly in knee ligament reconstruction. We hypothesize that 'BioCleanse®' processed bovine extensor digitorum medialis (EDM) tendons exhibit favorable time-zero pre-implantation biomechanical characteristics when compared to both unprocessed bovine EDM tendons and BioCleanse® processed human cadaveric allograft tibialis anterior tendons. In this in vitro case controlled laboratory study, three groups of tendons underwent a 5-stage static loading test protocol: 15 BioCleanse <superscript>®</superscript> bovine (BCB), 15 fresh frozen unprocessed bovine (FFB), and 12 BioCleanse <superscript>®</superscript> human allograft (BCA) tendons. Cross-sectional area of the grafts was measured using an alginate molding technique, and tendons were mounted within an Instron <superscript>®</superscript> 5565 Materials Testing System using cryogenic clamps. BCB tendons displayed a higher ultimate tensile stress (p<0.05), with equivalent ultimate failure load, creep, and modulus of elasticity when compared to the FFB tendons (p>0.05). BCB tendons had an equivalent cross-sectional area to the BCA tendons (p>0.05) whilst exhibiting a greater failure load, ultimate tensile stress, less creep and a higher modulus of elasticity (p<0.05). The BioCleanse <superscript>®</superscript> process did not adversely affect the time-zero biomechanical properties of bovine xenograft EDM tendons. BioCleanse <superscript>®</superscript> processed bovine xenograft EDM tendons exhibited superior biomechanical characteristics when compared with BioCleanse <superscript>®</superscript> processed allograft tibialis anterior tendons. These findings support further investigation of xenograft tendons in orthopedic soft tissue reconstructive surgery.<br /> (Copyright © 2017 Elsevier Ltd. All rights reserved.)
Details
- Language :
- English
- ISSN :
- 1873-2380
- Volume :
- 53
- Database :
- MEDLINE
- Journal :
- Journal of biomechanics
- Publication Type :
- Academic Journal
- Accession number :
- 28109536
- Full Text :
- https://doi.org/10.1016/j.jbiomech.2017.01.011