Back to Search Start Over

Biomechanical properties of bovine tendon xenografts treated with a modern processing method.

Authors :
Colaço HB
Lord BR
Back DL
Davies AJ
Amis AA
Ajuied A
Source :
Journal of biomechanics [J Biomech] 2017 Feb 28; Vol. 53, pp. 144-147. Date of Electronic Publication: 2017 Jan 13.
Publication Year :
2017

Abstract

Xenograft tendons have been used in few human studies, with variable results. With the advent of novel tissue processing techniques, which may mitigate against an immune-mediated rejection response without adversely affecting mechanical properties, there may now be a clinical role for xenograft tendons, particularly in knee ligament reconstruction. We hypothesize that 'BioCleanse®' processed bovine extensor digitorum medialis (EDM) tendons exhibit favorable time-zero pre-implantation biomechanical characteristics when compared to both unprocessed bovine EDM tendons and BioCleanse® processed human cadaveric allograft tibialis anterior tendons. In this in vitro case controlled laboratory study, three groups of tendons underwent a 5-stage static loading test protocol: 15 BioCleanse <superscript>®</superscript> bovine (BCB), 15 fresh frozen unprocessed bovine (FFB), and 12 BioCleanse <superscript>®</superscript> human allograft (BCA) tendons. Cross-sectional area of the grafts was measured using an alginate molding technique, and tendons were mounted within an Instron <superscript>®</superscript> 5565 Materials Testing System using cryogenic clamps. BCB tendons displayed a higher ultimate tensile stress (p<0.05), with equivalent ultimate failure load, creep, and modulus of elasticity when compared to the FFB tendons (p>0.05). BCB tendons had an equivalent cross-sectional area to the BCA tendons (p>0.05) whilst exhibiting a greater failure load, ultimate tensile stress, less creep and a higher modulus of elasticity (p<0.05). The BioCleanse <superscript>®</superscript> process did not adversely affect the time-zero biomechanical properties of bovine xenograft EDM tendons. BioCleanse <superscript>®</superscript> processed bovine xenograft EDM tendons exhibited superior biomechanical characteristics when compared with BioCleanse <superscript>®</superscript> processed allograft tibialis anterior tendons. These findings support further investigation of xenograft tendons in orthopedic soft tissue reconstructive surgery.<br /> (Copyright © 2017 Elsevier Ltd. All rights reserved.)

Details

Language :
English
ISSN :
1873-2380
Volume :
53
Database :
MEDLINE
Journal :
Journal of biomechanics
Publication Type :
Academic Journal
Accession number :
28109536
Full Text :
https://doi.org/10.1016/j.jbiomech.2017.01.011