Back to Search Start Over

Percutaneous Patent Ductus Arteriosus (PDA) Closure During Infancy: A Meta-analysis.

Authors :
Backes CH
Rivera BK
Bridge JA
Armstrong AK
Boe BA
Berman DP
Fick T
Holzer RJ
Hijazi ZM
Abadir S
Justino H
Bergersen L
Smith CV
Kirpalani H
Source :
Pediatrics [Pediatrics] 2017 Feb; Vol. 139 (2). Date of Electronic Publication: 2017 Jan 13.
Publication Year :
2017

Abstract

Context: Patent ductus arteriosus (PDA) is a precursor to morbidity and mortality. Percutaneous (catheter-based) closure is the procedure of choice for adults and older children with a PDA, but use during infancy (<1 year) is not well characterized.<br />Objective: Investigate the technical success and safety of percutaneous PDA closure during infancy.<br />Data Sources: Scopus, Web of Science, Embase, PubMed, and Ovid (Medline) were searched through December 2015 with no language restrictions.<br />Study Selection: Publications needed to clearly define the intervention as percutaneous PDA closure during infancy (<1 year of age at intervention) and must have reported adverse events (AEs).<br />Data Extraction: The study was performed according to the Systematic Reviews and Meta-Analysis checklist and registered prospectively. The quality of the selected studies was critically examined. Data extraction and assignment of AE attributability and severity were independently performed by multiple observers. Outcomes were agreed on a priori. Data were pooled by using a random-effects model.<br />Results: Thirty-eight studies were included; no randomized controlled trials were found. Technical success of percutaneous PDA closure was 92.2% (95% confidence interval [CI] 88.8-95.0). Overall AE and clinically significant AE incidence was 23.3% (95% CI 16.5-30.8) and 10.1% (95% CI 7.8-12.5), respectively. Significant heterogeneity and publication bias were observed.<br />Limitations: Limitations include lack of comparative studies, lack of standardized AE reporting strategy, and significant heterogeneity in reporting.<br />Conclusions: Percutaneous PDA closure during infancy is feasible and associated with few catastrophic AEs; however, the limitations constrain the interpretability and generalizability of the current findings.<br /> (Copyright © 2017 by the American Academy of Pediatrics.)

Details

Language :
English
ISSN :
1098-4275
Volume :
139
Issue :
2
Database :
MEDLINE
Journal :
Pediatrics
Publication Type :
Academic Journal
Accession number :
28087683
Full Text :
https://doi.org/10.1542/peds.2016-2927