Back to Search
Start Over
Three-dimensional virtual bronchoscopy using a tablet computer to guide real-time transbronchial needle aspiration.
- Source :
-
Interactive cardiovascular and thoracic surgery [Interact Cardiovasc Thorac Surg] 2017 Apr 01; Vol. 24 (4), pp. 567-575. - Publication Year :
- 2017
-
Abstract
- Objectives: We proposed a new virtual bronchoscopy tool to improve the accuracy of traditional transbronchial needle aspiration for mediastinal staging.<br />Methods: Chest-computed tomographic images (1 mm thickness) were reconstructed with Osirix software to produce a virtual bronchoscopic simulation. The target adenopathy was identified by measuring its distance from the carina on multiplanar reconstruction images. The static images were uploaded in iMovie Software, which produced a virtual bronchoscopic movie from the images; the movie was then transferred to a tablet computer to provide real-time guidance during a biopsy. To test the validity of our tool, we divided all consecutive patients undergoing transbronchial needle aspiration retrospectively in two groups based on whether the biopsy was guided by virtual bronchoscopy (virtual bronchoscopy group) or not (traditional group). The intergroup diagnostic yields were statistically compared.<br />Results: Our analysis included 53 patients in the traditional and 53 in the virtual bronchoscopy group. The sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy for the traditional group were 66.6%, 100%, 100%, 10.53% and 67.92%, respectively, and for the virtual bronchoscopy group were 84.31%, 100%, 100%, 20% and 84.91%, respectively. The sensitivity ( P = 0.011) and diagnostic accuracy ( P = 0.011) of sampling the paratracheal station were better for the virtual bronchoscopy group than for the traditional group; no significant differences were found for the subcarinal lymph node.<br />Conclusions: Our tool is simple, economic and available in all centres. It guided in real time the needle insertion, thereby improving the accuracy of traditional transbronchial needle aspiration, especially when target lesions are located in a difficult site like the paratracheal station.<br /> (© The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.)
- Subjects :
- Adult
Aged
Female
Humans
Lymph Nodes pathology
Male
Mediastinum pathology
Middle Aged
Neoplasm Staging
Retrospective Studies
Sensitivity and Specificity
Software
Tomography, X-Ray Computed
Biopsy, Needle methods
Bronchoscopy methods
Carcinoma, Non-Small-Cell Lung pathology
Computers, Handheld
Imaging, Three-Dimensional
Lung Neoplasms pathology
Subjects
Details
- Language :
- English
- ISSN :
- 1569-9285
- Volume :
- 24
- Issue :
- 4
- Database :
- MEDLINE
- Journal :
- Interactive cardiovascular and thoracic surgery
- Publication Type :
- Academic Journal
- Accession number :
- 28040772
- Full Text :
- https://doi.org/10.1093/icvts/ivw404