Determination of overt carnitine palmitoyltransferase by reversed-phase high-performance liquid chromatography.

Authors :
Takeyama N
Matsuo N
Takagi D
Tanaka T
Source :
Journal of chromatography [J Chromatogr] 1989 Jun 30; Vol. 491 (1), pp. 69-76.
Publication Year :
1989

Abstract

A method for the determination of carnitine palmitoyltransferase I (CPT I; EC 2.3.1.19) in isolated rat liver mitochondria by reversed-phase high-performance liquid chromatography is described. Enzyme activity is assayed by direct determination of coenzyme A (CoA) released from palmitoyl-CoA within 60 min by a linear gradient system. CPT 1 in rat liver mitochondria can be assayed from only 30 micrograms of mitochondrial protein per millilitre of assay mixture. The changes in the kinetic parameters of CPT I, including Ki for malonyl-CoA, resulting from the fasting-feeding cycle are also discussed.