Back to Search Start Over

Simultaneous determination of midazolam and its three hydroxy metabolites in human plasma by electron-capture gas chromatography without derivatization.

Authors :
De Kroon IF
Langendijk PN
De Goede PN
Source :
Journal of chromatography [J Chromatogr] 1989 Jun 30; Vol. 491 (1), pp. 107-16.
Publication Year :
1989

Abstract

Electron-capture gas chromatography was carried out to determine midazolam and its three hydroxy metabolites (1-hydroxymethylmidazolam, 4-hydroxymidazolam and 1-hydroxymethyl-4-hydroxymidazolam) in human plasma. The assay involves extraction from plasma, buffered to pH 9.3, into cyclohexane-dichloromethane (6:4) and analysis by gas chromatography. The use of an HP-17 cross-linked, capillary column makes derivatization unnecessary. The sensitivity of the method was 2-3 ng/ml for midazolam, 1-hydroxymethylmidazolam and 4-hydroxymidazolam, and 20 ng/ml for 1-hydroxymethyl-4-hydroxymidazolam. The extraction recovery of midazolam, 1-hydroxymethylmidazolam, 4-hydroxymidazolam and 1-hydroxymethyl-4-hydroxymidazolam was 99.3 +/- 2.4, 67.0 +/- 4.6, 92.7 +/- 4.7 and 28.7 +/- 6.3%, respectively. This gas chromatographic assay was used to assess the concentration-time profiles of midazolam and its metabolites in human plasma after rectal and intravenous administration of midazolam.

Details

Language :
English
Volume :
491
Issue :
1
Database :
MEDLINE
Journal :
Journal of chromatography
Publication Type :
Academic Journal
Accession number :
2793966