Back to Search Start Over

The development of a whole-head human finite-element model for simulation of the transmission of bone-conducted sound.

Authors :
Chang Y
Kim N
Stenfelt S
Source :
The Journal of the Acoustical Society of America [J Acoust Soc Am] 2016 Sep; Vol. 140 (3), pp. 1635.
Publication Year :
2016

Abstract

A whole head finite element model for simulation of bone conducted (BC) sound transmission was developed. The geometry and structures were identified from cryosectional images of a female human head and eight different components were included in the model: cerebrospinal fluid, brain, three layers of bone, soft tissue, eye, and cartilage. The skull bone was modeled as a sandwich structure with an inner and outer layer of cortical bone and soft spongy bone (diploë) in between. The behavior of the finite element model was validated against experimental data of mechanical point impedance, vibration of the cochlear promontories, and transcranial BC sound transmission. The experimental data were obtained in both cadaver heads and live humans. The simulations showed multiple low-frequency resonances where the first was caused by rotation of the head and the second was close in frequency to average resonances obtained in cadaver heads. At higher frequencies, the simulation results of the impedance were within one standard deviation of the average experimental data. The acceleration response at the cochlear promontory was overall lower for the simulations compared with experiments but the overall tendencies were similar. Even if the current model cannot predict results in a specific individual, it can be used for understanding the characteristic of BC sound transmission in general.

Details

Language :
English
ISSN :
1520-8524
Volume :
140
Issue :
3
Database :
MEDLINE
Journal :
The Journal of the Acoustical Society of America
Publication Type :
Academic Journal
Accession number :
27914383
Full Text :
https://doi.org/10.1121/1.4962443