Back to Search
Start Over
Total hip arthroplasty using a cementless dual-mobility cup provides increased stability and favorable gait parameters at five years follow-up.
- Source :
-
Orthopaedics & traumatology, surgery & research : OTSR [Orthop Traumatol Surg Res] 2017 Feb; Vol. 103 (1), pp. 21-25. Date of Electronic Publication: 2016 Nov 24. - Publication Year :
- 2017
-
Abstract
- Background: Rates of dislocation following primary total hip arthroplasty (THA) vary from 0.5 to 10%. Dual-mobility cups in THA demonstrate increased stability. Clinical outcomes following THA with dual-mobility cups have been reported, but gait has not been assessed. Therefore we performed a retrospective case control study to answer: (1) is gait better in patients following THA with a dual-mobility cup than in frail, elderly patients of the same age? (2) Are clinical outcomes better in patients following THA with a dual-mobility cup than in frail, elderly patients? (3) What is the dislocation rate following THA with a dual-mobility cup?<br />Hypothesis: We hypothesized that patients who underwent THA with a dual-mobility cup have a better gait compared to frail, elderly patients of the same age.<br />Patients and Methods: Twenty patients (22 hips), mean age 79.9±7.7 (range, 62.3-88.3) years were assessed in this retrospective case-control series 5.6±1.4 (range: 4.1-8.8) years following dual-mobility cup THA. A reference group consisted of 72 "frail elderly" patients in a rehabilitation hospital for health problems unrelated to the lower limb, with no lower limb surgery or neurological conditions. Temporal and spatial gait performance were measured with four miniature gyroscopes, mounted on each thigh and calf, while patients walked freely along a 30m corridor. Harris Hip Score, WOMAC, radiological outcomes, and dislocation rate were determined.<br />Results: All gait parameters were better in the dual-mobility group compared to the frail elderly group. The dual-mobility group had a higher cadence (100.3 steps/minute versus 75.6 steps/minute), shorter (relative to gait cycle time) stance (61.6% versus 67.8%), shorter (relative to gait cycle time) double stance (23.3% versus 36.0%), longer stride (1.13m versus 0.80m), and faster walking speed (0.96m/s versus 0.52m/s). Range of motion of the shank, thigh and knee were better in the dual-mobility group. Harris Hip Score was 87.6±13.9 (range 51-100) and WOMAC score was 11.3±12.1 (range 0-34) in the THA group. We observed no dislocations.<br />Discussion: Gait patterns five years following THA with the dual-mobility cup were better or comparable to published study populations.<br />Level of Evidence: III, retrospective case-control series.<br /> (Copyright © 2016 Elsevier Masson SAS. All rights reserved.)
- Subjects :
- Aged
Aged, 80 and over
Arthroplasty, Replacement, Hip adverse effects
Case-Control Studies
Female
Follow-Up Studies
Frail Elderly
Humans
Joint Instability etiology
Knee Joint physiopathology
Male
Middle Aged
Radiography
Range of Motion, Articular
Retrospective Studies
Treatment Outcome
Walking
Arthroplasty, Replacement, Hip instrumentation
Gait
Hip Dislocation etiology
Hip Joint physiopathology
Hip Prosthesis adverse effects
Subjects
Details
- Language :
- English
- ISSN :
- 1877-0568
- Volume :
- 103
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- Orthopaedics & traumatology, surgery & research : OTSR
- Publication Type :
- Academic Journal
- Accession number :
- 27890581
- Full Text :
- https://doi.org/10.1016/j.otsr.2016.09.020