Back to Search Start Over

Clinical evaluation of a radio-protective cream for the hands of the pediatric interventional cardiologist.

Authors :
Subramanian S
Waller BR
Winders N
Bird LE
Agrawal V
Zurakowski D
Kuhls-Gilcrist A
Khandkar A
Sathanandam SK
Source :
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions [Catheter Cardiovasc Interv] 2017 Mar 01; Vol. 89 (4), pp. 709-716. Date of Electronic Publication: 2016 Nov 26.
Publication Year :
2017

Abstract

Objectives: The aim of this study was to evaluate the effectiveness of UltraBLOX™ radiation attenuating hand cream during lengthy cardiac catheterization procedures in children.<br />Background: The hands of interventional cardiologists receive high doses of radiation due to their proximity to the X-ray beam. Radiation attenuating gloves have about a 26% attenuation rate, but reduce dexterity and tactile sensation. The UltraBLOX™ cream is a new FDA-approved X-ray attenuating cream that can be applied to the operator's hands for radio-protection.<br />Methods: Two nanoDot™ dosimeters were secured side by side on the dorsum of the operator's (n = 2) left hand close to the wrist. One dosimeter and the rest of the hand were covered with 0.2 mm layer of the cream. The other dosimeter was unshielded. Procedures were performed using 110 kVp fluoroscopy at 15 pulses/sec. The measurements were categorized into four groups dependent on the duration of the procedure. The patients in all four groups were well matched for age and size.<br />Results: Procedural and cumulative hand radiation doses were higher with longer procedural duration. The overall % attenuation by the cream was 39.7% (28.6-51.5) and was unaffected by the length of the procedure (median: 40.9% at 30 min and 41.4% at 180 min; P = 0.66) or the dose of radiation. The kappa statistic for interobserver agreement for good tactile sensitivity was 0.82.<br />Conclusions: UltraBLOX™ cream provides a new option for radio-protection for the hands of interventional cardiologists without impairing tactile sensitivity. There was no decrease in attenuation up to 180 min. © 2016 Wiley Periodicals, Inc.<br /> (© 2016 Wiley Periodicals, Inc.)

Details

Language :
English
ISSN :
1522-726X
Volume :
89
Issue :
4
Database :
MEDLINE
Journal :
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions
Publication Type :
Academic Journal
Accession number :
27888578
Full Text :
https://doi.org/10.1002/ccd.26845