Back to Search Start Over

Body surface mapping using an ECG belt to characterize electrical heterogeneity for different left ventricular pacing sites during cardiac resynchronization: Relationship with acute hemodynamic improvement.

Authors :
Johnson WB
Vatterott PJ
Peterson MA
Bagwe S
Underwood RD
Bank AJ
Gage RM
Ramza B
Foreman BW
Splett V
Haddad T
Gillberg JM
Ghosh S
Source :
Heart rhythm [Heart Rhythm] 2017 Mar; Vol. 14 (3), pp. 385-391. Date of Electronic Publication: 2016 Nov 18.
Publication Year :
2017

Abstract

Background: Electrical heterogeneity (EH) during cardiac resynchronization therapy may vary with different left ventricular (LV) pacing sites.<br />Objective: The purpose of this study was to evaluate the relationship between such changes and acute hemodynamic response (AHR).<br />Methods: Two EH metrics-standard deviation of activation times and mean left thorax activation times-were computed from isochronal maps based on 53-electrode body surface mapping during baseline AAI pacing and biventricular (BiV) pacing from different pacing sites in coronary veins in 40 cardiac resynchronization therapy-indicated patients. AHR at different sites was evaluated by invasive measurement of LV-dp/dt <subscript>max</subscript> at baseline and BiV pacing, along with right ventricular (RV)-LV sensing delays and QRS duration.<br />Results: The site with the greatest combined reduction in standard deviation of activation times and left thorax activation times from baseline to BiV pacing was hemodynamically optimal (defined by AHR equal to, or within 5% of, the largest dp/dt response) in 35 of 40 patients (88%). Sites with the longest RV-LV and narrowest paced QRS were hemodynamically optimal in 26 of 40 patients (65%) and 28 of 40 patients (70%), respectively. EH metrics from isochronal maps had much better accuracy (sensitivity 90%, specificity 80%) for identifying hemodynamically responsive sites (∆LV dp/dt <subscript>max</subscript> ≥10%) compared with RV-LV delay (69%, 85%) or paced QRS reduction (52%, 76%). Multivariate prediction model based on EH metrics showed significant correlation (R <superscript>2</superscript> = 0.53, P <.001) between predicted and measured AHR.<br />Conclusion: Changes in EH from baseline to BiV pacing more accurately identified hemodynamically optimal sites than RV-LV delays or paced QRS shortening. Optimization of LV lead location by minimizing EH during BiV pacing, based on body surface mapping, may improve CRT response.<br /> (Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
1556-3871
Volume :
14
Issue :
3
Database :
MEDLINE
Journal :
Heart rhythm
Publication Type :
Academic Journal
Accession number :
27871987
Full Text :
https://doi.org/10.1016/j.hrthm.2016.11.017