Back to Search
Start Over
Spot-Scanning Proton Arc (SPArc) Therapy: The First Robust and Delivery-Efficient Spot-Scanning Proton Arc Therapy.
- Source :
-
International journal of radiation oncology, biology, physics [Int J Radiat Oncol Biol Phys] 2016 Dec 01; Vol. 96 (5), pp. 1107-1116. Date of Electronic Publication: 2016 Sep 07. - Publication Year :
- 2016
-
Abstract
- Purpose: To present a novel robust and delivery-efficient spot-scanning proton arc (SPArc) therapy technique.<br />Methods and Materials: A SPArc optimization algorithm was developed that integrates control point resampling, energy layer redistribution, energy layer filtration, and energy layer resampling. The feasibility of such a technique was evaluated using sample patients: 1 patient with locally advanced head and neck oropharyngeal cancer with bilateral lymph node coverage, and 1 with a nonmobile lung cancer. Plan quality, robustness, and total estimated delivery time were compared with the robust optimized multifield step-and-shoot arc plan without SPArc optimization (Arc <subscript>multi-field</subscript> ) and the standard robust optimized intensity modulated proton therapy (IMPT) plan. Dose-volume histograms of target and organs at risk were analyzed, taking into account the setup and range uncertainties. Total delivery time was calculated on the basis of a 360° gantry room with 1 revolutions per minute gantry rotation speed, 2-millisecond spot switching time, 1-nA beam current, 0.01 minimum spot monitor unit, and energy layer switching time of 0.5 to 4 seconds.<br />Results: The SPArc plan showed potential dosimetric advantages for both clinical sample cases. Compared with IMPT, SPArc delivered 8% and 14% less integral dose for oropharyngeal and lung cancer cases, respectively. Furthermore, evaluating the lung cancer plan compared with IMPT, it was evident that the maximum skin dose, the mean lung dose, and the maximum dose to ribs were reduced by 60%, 15%, and 35%, respectively, whereas the conformity index was improved from 7.6 (IMPT) to 4.0 (SPArc). The total treatment delivery time for lung and oropharyngeal cancer patients was reduced by 55% to 60% and 56% to 67%, respectively, when compared with Arc <subscript>multi-field</subscript> plans.<br />Conclusion: The SPArc plan is the first robust and delivery-efficient proton spot-scanning arc therapy technique, which could potentially be implemented into routine clinical practice.<br /> (Copyright © 2016 Elsevier Inc. All rights reserved.)
- Subjects :
- Algorithms
Carcinoma, Non-Small-Cell Lung diagnostic imaging
Feasibility Studies
Humans
Lung Neoplasms diagnostic imaging
Organs at Risk diagnostic imaging
Oropharyngeal Neoplasms diagnostic imaging
Quality Improvement
Radiotherapy Dosage
Time Factors
Carcinoma, Non-Small-Cell Lung radiotherapy
Lung Neoplasms radiotherapy
Oropharyngeal Neoplasms radiotherapy
Proton Therapy methods
Radiotherapy Planning, Computer-Assisted methods
Radiotherapy, Intensity-Modulated methods
Subjects
Details
- Language :
- English
- ISSN :
- 1879-355X
- Volume :
- 96
- Issue :
- 5
- Database :
- MEDLINE
- Journal :
- International journal of radiation oncology, biology, physics
- Publication Type :
- Academic Journal
- Accession number :
- 27869083
- Full Text :
- https://doi.org/10.1016/j.ijrobp.2016.08.049