Back to Search Start Over

Geographical miss of the prostate during image-guided radiotherapy with a 6-mm posterior expansion margin.

Authors :
Oates R
Jones D
Foroudi F
Gill S
Ramachandran P
Schneider M
Lim Joon M
Kron T
Source :
Journal of medical radiation sciences [J Med Radiat Sci] 2017 Jun; Vol. 64 (2), pp. 97-105. Date of Electronic Publication: 2016 Nov 08.
Publication Year :
2017

Abstract

Introduction: Our department commonly uses a planning target volume (PTV) expansion of 6 mm posterior and 1 cm in all other directions when treating prostate cancer patients with image-guided radiotherapy (IGRT). This study aimed to test the adequacy of this PTV expansion by assessing geographical miss of the prostate on post-treatment cone-beam CT (CBCT) and identify those at risk of geographical miss.<br />Methods: Twenty-two prostate cancer patients receiving IGRT with implanted fiducial markers underwent daily pre-treatment orthogonal kV imaging followed by a post-treatment CBCT for a total of 432 fractions. The prostate was outlined on all CBCTs. For each imaging set, the volume of geographic miss was measured by subtracting the PTV from the planning CT and prostate volume on the post-treatment CBCT.<br />Results: The prostate volume moved outside the PTV by >0.01 cc in 9% of fractions (39/432). This occurred in 13 (59%) of 22 patients. Large prostates >40 cc and >50 cc had significantly more geographical miss events (both P < 0.001). Changes in rectal filling appear to be responsible for prostate motion/deformation in 82% (32/39) of fractions.<br />Conclusions: Our analysis suggests that, despite IGRT, prostate PTV margins are not adequate in some patients, particularly those with large prostates. PTV margins may be reduced in some other patients. Prostate rotation and deformation play an important role in setting margins and may not always be represented accurately by fiducial marker displacements. Individualised and adaptive margins for prostate cancer patients should be a priority for future research.<br /> (© 2016 The Authors. Journal of Medical Radiation Sciences published by John Wiley & Sons Australia, Ltd on behalf of Australian Society of Medical Imaging and Radiation Therapy and New Zealand Institute of Medical Radiation Technology.)

Details

Language :
English
ISSN :
2051-3909
Volume :
64
Issue :
2
Database :
MEDLINE
Journal :
Journal of medical radiation sciences
Publication Type :
Academic Journal
Accession number :
27860454
Full Text :
https://doi.org/10.1002/jmrs.186