Back to Search Start Over

An in vitro investigation to assess procedure parameters for injecting therapeutic hydrogels into the myocardium.

Authors :
Curley CJ
Dolan EB
Cavanagh B
O'Sullivan J
Duffy GP
Murphy BP
Source :
Journal of biomedical materials research. Part B, Applied biomaterials [J Biomed Mater Res B Appl Biomater] 2017 Nov; Vol. 105 (8), pp. 2618-2629. Date of Electronic Publication: 2016 Oct 20.
Publication Year :
2017

Abstract

Localized delivery of stem cells is potentially a promising therapeutic strategy for regenerating damaged myocardium. Many studies focus on limiting the biologic component of cell loss, but few address the contribution of mechanical factors. This study investigates optimal parameters for retaining the largest volume of cell loaded hydrogels post intramyocardial injection, without compromising cell viability. In vitro, hydrogel was injected into porcine hearts using various needle designs. Hydrogel retention and distribution pattern was then determined. The two most promising needles were then investigated to understand the effect of needle geometry on stem cell viability. The needle to best impact cell viability was then used to investigate the effect of differing hydrogels on retention and distribution. Three-dimensional experimental modeling revealed needles with smaller diameter's to have greater poloxamer 407 hydrogel retention. No difference in retention existed among various needle designs of similar gauge, despite differences in bolus geometries. When hMSC's, embedded in fibrin hydrogel, were injected through helical and 26G bevel needles no difference in the percent of live cells was seen at 48 h. However, the helical group had almost half the metabolic activity of the 26G bevel group at both time points, and had a significant decline in the percent of live cells from 24 to 48 h. Varying gel type resulted in significantly more alginate being retained in the tissue in comparison to fibrin or poloxamer hydrogels. In conclusion, mechanical properties of injected hydrogels, and the diameter of the needle used, highly influences the volume of hydrogel retained. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 2618-2629, 2017.<br /> (© 2016 Wiley Periodicals, Inc.)

Details

Language :
English
ISSN :
1552-4981
Volume :
105
Issue :
8
Database :
MEDLINE
Journal :
Journal of biomedical materials research. Part B, Applied biomaterials
Publication Type :
Academic Journal
Accession number :
27764526
Full Text :
https://doi.org/10.1002/jbm.b.33802