Trans-catheter aortic valve implantation with the direct flow medical prosthesis: Single center short-term clinical and echocardiographic outcomes.
- Source :
-
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions [Catheter Cardiovasc Interv] 2017 Feb 15; Vol. 89 (3), pp. 420-428. Date of Electronic Publication: 2016 Oct 14. - Publication Year :
- 2017
-
Abstract
- Objectives: To analyze our single center experience with the Direct Flow Medical (DFM).<br />Background: The DFM has been recently introduced to the market and large real world experiences are lacking.<br />Methods: A total of 126 patients with severe aortic valve stenosis (AVS) were treated by the same team from March 2013 to May 2015. Device success and procedural safety were classified, according to valve academic research consortium (VARC) criteria, for the entire cohort, including patients treated in the early phases of our learning curve.<br />Results: Clinical and trans-thoracic echocardiography follow-up was performed (median duration 279 days; 36-761 days). Mean age was 80.9 ± 5.5 years and median logistic Euro-SCORE was 15.9 (5.5-84.2). Cardiovascular 30-day mortality was 4.8% (6/126), device success 89.6% (113/126), and early safety 85.7% (108/126). At discharge, no aortic regurgitation (AR) was present in 85.7% and mild AR in 14.3% of the patients. Estimated 1-year follow-up survival was 91%. At follow-up, no AR was present in 87.3%, mild AR in 10.9%, and moderate AR in 1.8%. Mean gradient of 15.1 ± 6.3 mm Hg and prosthesis effective orifice area of 1.6 ± 0.6 cm <superscript>2</superscript> were reported.<br />Conclusions: In this single center experience, the DFM valve showed satisfactory clinical and hemodynamic results. Short-term follow-up confirmed the consistent clinical results, with low rates of AR and acceptable trans-prosthetic gradients and prosthetic effective orifice area. © 2016 Wiley Periodicals, Inc.<br /> (© 2016 Wiley Periodicals, Inc.)
- Subjects :
- Aged
Aged, 80 and over
Aortic Valve physiopathology
Aortic Valve Stenosis diagnostic imaging
Aortic Valve Stenosis mortality
Aortic Valve Stenosis physiopathology
Cardiac Catheterization methods
Cardiac Catheterization mortality
Female
Germany
Heart Valve Prosthesis Implantation methods
Heart Valve Prosthesis Implantation mortality
Humans
Kaplan-Meier Estimate
Learning Curve
Male
Patient Selection
Predictive Value of Tests
Prosthesis Design
Retrospective Studies
Risk Factors
Severity of Illness Index
Time Factors
Treatment Outcome
Aortic Valve diagnostic imaging
Aortic Valve Stenosis therapy
Cardiac Catheterization instrumentation
Echocardiography
Heart Valve Prosthesis
Heart Valve Prosthesis Implantation instrumentation
Hemodynamics
Subjects
Details
- Language :
- English
- ISSN :
- 1522-726X
- Volume :
- 89
- Issue :
- 3
- Database :
- MEDLINE
- Journal :
- Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions
- Publication Type :
- Academic Journal
- Accession number :
- 27739170
- Full Text :
- https://doi.org/10.1002/ccd.26528