Back to Search
Start Over
A novel approach for left ventricular lead placement in cardiac resynchronization therapy: Intraprocedural integration of coronary venous electroanatomic mapping with delayed enhancement cardiac magnetic resonance imaging.
- Source :
-
Heart rhythm [Heart Rhythm] 2017 Jan; Vol. 14 (1), pp. 110-119. Date of Electronic Publication: 2016 Sep 20. - Publication Year :
- 2017
-
Abstract
- Background: Placing the left ventricular (LV) lead at a site of late electrical activation remote from scar is desired to improve cardiac resynchronization therapy (CRT) response.<br />Objective: The purpose of this study was to integrate coronary venous electroanatomic mapping (EAM) with delayed enhancement cardiac magnetic resonance (DE-CMR) enabling LV lead guidance to the latest activated vein remote from scar.<br />Methods: Eighteen CRT candidates with focal scar on DE-CMR were prospectively included. DE-CMR images were semi-automatically analyzed. Coronary venous EAM was performed intraprocedurally and integrated with DE-CMR to guide LV lead placement in real time. Image integration accuracy and electrogram parameters were evaluated offline.<br />Results: Integration of EAM and DE-CMR was achieved using 8.9 ± 2.8 anatomic landmarks and with accuracy of 4.7 ± 1.1 mm (mean ± SD). Maximal electrical delay ranged between 72 and 197ms (57%-113% of QRS duration) and was heterogeneously located among individuals. In 12 patients, the latest activated vein was located outside scar, and placing the LV lead in the latest activated vein remote from scar was accomplished in 10 patients and prohibited in 2 patients. In the other 6 patients, the latest activated vein was located in scar, and targeting alternative veins was considered. Unipolar voltages were on average lower in scar compared to nonscar (6.71 ± 3.45 mV vs 8.18 ± 4.02 mV [median ± interquartile range), P <.001) but correlated weakly with DE-CMR scar extent (R -0.161, P <.001) and varied widely among individual patients.<br />Conclusion: Integration of coronary venous EAM with DE-CMR can be used during CRT implantation to guide LV lead placement to the latest activated vein remote from scar, possibly improving CRT.<br /> (Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.)
- Subjects :
- Aged
Cohort Studies
Electrodes, Implanted
Female
Heart Failure diagnosis
Heart Failure mortality
Humans
Male
Middle Aged
Prognosis
Prospective Studies
Risk Assessment
Severity of Illness Index
Statistics, Nonparametric
Survival Analysis
Treatment Outcome
Body Surface Potential Mapping methods
Cardiac Resynchronization Therapy methods
Coronary Vessels diagnostic imaging
Heart Failure therapy
Magnetic Resonance Imaging, Cine methods
Subjects
Details
- Language :
- English
- ISSN :
- 1556-3871
- Volume :
- 14
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- Heart rhythm
- Publication Type :
- Academic Journal
- Accession number :
- 27663606
- Full Text :
- https://doi.org/10.1016/j.hrthm.2016.09.015