Back to Search
Start Over
Structural Damage of Jailed Guidewire During the Treatment of Coronary Bifurcation Lesions: A Microscopic Randomized Trial.
- Source :
-
JACC. Cardiovascular interventions [JACC Cardiovasc Interv] 2016 Sep 26; Vol. 9 (18), pp. 1917-24. - Publication Year :
- 2016
-
Abstract
- Objectives: The study sought to compare the safety (resistance to damage) and efficacy (ability to cross the side branch) of polymer-coated and non-polymer-coated guidewires in the jailed wire technique used during the percutaneous treatment of bifurcation lesions.<br />Background: The jailed wire technique is a useful strategy in the treatment of bifurcation lesions by provisional stenting. However, these wires can be damaged or even be broken during their removal.<br />Methods: We performed a randomized study in patients with bifurcation lesions treated by provisional stenting. The jailed wire technique was mandatory, and the types of guidewires, polymer-coated (n = 115) and non-polymer-coated (n = 120), were randomized. After the procedures, the wires were evaluated by stereoscopic microscopy. The induced damage in the wires was classified as follows: no damage, mild, moderate, or severe.<br />Results: The clinical characteristics were similar between patients treated with polymer-coated or non-polymer-coated wires. Polymer-coated wires were significantly (p < 0.001) more resistant to retrieval damage (only 2 wires showed mild damage) than were non-polymer-coated wires. However, 63 (55%) of the non-polymer-coated wires were damaged; 37 (32%), 24 (21%), and 2 (2%) had mild, moderate, and severe damage, respectively. Additionally, the jailed length of the wire was a factor contributing to the degree of wire damage. The time of side branch wiring was shorter in the polymer-coated wire group (19 ± 40 s vs. 42 ± 72 s; p < 0.05).<br />Conclusions: Jailed wires during interventional procedures of bifurcation lesions commonly showed microscopic damage. Polymer-coated wires were more resistant to retrieval damage and were more efficient in crossing the side branch ostium than non-polymer-coated wires. (Jailed Wire Technique in the Treatment of Coronary Bifurcations Lesions With Stent: Stereoscopic Microscopy Study; NCT02516891).<br /> (Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.)
- Subjects :
- Aged
Coronary Angiography
Coronary Artery Disease diagnostic imaging
Equipment Design
Female
Humans
Male
Middle Aged
Percutaneous Coronary Intervention adverse effects
Prospective Studies
Single-Blind Method
Spain
Stents
Treatment Outcome
Cardiac Catheters
Coated Materials, Biocompatible
Coronary Artery Disease therapy
Equipment Failure
Microscopy methods
Percutaneous Coronary Intervention instrumentation
Polymers chemistry
Subjects
Details
- Language :
- English
- ISSN :
- 1876-7605
- Volume :
- 9
- Issue :
- 18
- Database :
- MEDLINE
- Journal :
- JACC. Cardiovascular interventions
- Publication Type :
- Academic Journal
- Accession number :
- 27659568
- Full Text :
- https://doi.org/10.1016/j.jcin.2016.06.030