Promoting False-Lumen Thrombosis after Thoracic Endovascular Aneurysm Repair in Type B Aortic Dissection by Selectively Excluding False-Lumen Distal Entry Tears.
- Source :
-
Journal of vascular and interventional radiology : JVIR [J Vasc Interv Radiol] 2017 Feb; Vol. 28 (2), pp. 168-175. Date of Electronic Publication: 2016 Sep 16. - Publication Year :
- 2017
-
Abstract
- Purpose: To evaluate the efficacy and clinical outcomes of ancillary endovascular procedures in promoting false-lumen (FL) thrombosis (FLT) and preventing aortic expansion in patients after thoracic endografting for type B dissections.<br />Materials and Methods: This retrospective review included 15 patients (12 men and 3 women; mean age, 59.6 y). Mean aortic diameter at the time of ancillary treatment was 47.4 mm. Different techniques were used as single procedures or sequentially: covered stent occlusion of detached visceral artery entry tears, occlusion of single entry tears with vascular plugs, or aortic endograft occlusion of multiple FL entry tears. FL embolization with ethylene vinyl alcohol copolymer was performed when selective occlusion was considered insufficient to close distal entry tears. Apart from endovascular aneurysm repair, all procedures were performed percutaneously under local anesthesia. If FL diameter increase persisted after 6-month follow-up computed tomographic (CT) angiography, another intervention was planned; otherwise, yearly follow-up was performed.<br />Results: Mean clinical follow-up duration was 43.8 months (range, 8 d to 86.8 mo), with no in-hospital mortality. Estimated overall survival rates were 93.3%, 86.6%, and 77% at 12, 24, and 48 months, respectively. Three late deaths occurred, one of which was dissection-related at 40 months. Eight surviving patients (53%) had total FLT and 3 had partial FLT with stable aortic diameter on follow-up CT angiography. FL diameter increased in one patient, requiring further intervention.<br />Conclusions: Selective exclusion of new distal entry tears remaining after thoracic endovascular aneurysm repair can stabilize abdominal aortic expansion and promote FLT.<br /> (Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.)
- Subjects :
- Aortic Dissection diagnostic imaging
Aortic Aneurysm, Thoracic diagnostic imaging
Aortography methods
Blood Vessel Prosthesis
Computed Tomography Angiography
Embolization, Therapeutic adverse effects
Female
Humans
Male
Middle Aged
Polyvinyls adverse effects
Retrospective Studies
Stents
Time Factors
Treatment Outcome
Aortic Dissection surgery
Aortic Aneurysm, Thoracic surgery
Blood Vessel Prosthesis Implantation adverse effects
Blood Vessel Prosthesis Implantation instrumentation
Embolization, Therapeutic methods
Endovascular Procedures adverse effects
Endovascular Procedures instrumentation
Polyvinyls administration & dosage
Thrombosis
Subjects
Details
- Language :
- English
- ISSN :
- 1535-7732
- Volume :
- 28
- Issue :
- 2
- Database :
- MEDLINE
- Journal :
- Journal of vascular and interventional radiology : JVIR
- Publication Type :
- Academic Journal
- Accession number :
- 27645464
- Full Text :
- https://doi.org/10.1016/j.jvir.2016.07.007