Back to Search Start Over

T1-weighted MR imaging of glioma at 3T: a comparative study of 3D MPRAGE vs. conventional 2D spin-echo imaging.

Authors :
Dodo T
Okada T
Yamamoto A
Kanagaki M
Fushimi Y
Okada T
Sakata A
Arakawa Y
Miyamoto S
Togashi K
Source :
Clinical imaging [Clin Imaging] 2016 Nov - Dec; Vol. 40 (6), pp. 1257-1261. Date of Electronic Publication: 2016 Aug 26.
Publication Year :
2016

Abstract

Purpose: This study aims to investigate difference between magnetization-prepared rapid gradient-echo imaging (MPRAGE) and spin-echo (SE) imaging for evaluating glioma on pre-contrast-enhanced (CE) and post-CE T1-weighted images at 3 T.<br />Materials and Methods: We retrospectively assessed pre-CE and post-CE T1-weighted images for tumor contrast in 64 consecutive glioma patients.<br />Results: In the nonenhancing tumors, the contrast was significantly clearer in MPRAGE than SE. In the enhancing tumors, post-CE contrast ratio was significantly higher in SE than MPRAGE, but when subtraction images are evaluated, the difference got smaller.<br />Conclusion: MPRAGE can be a good substitute of SE for T1-weighted imaging of glioma.<br /> (Copyright © 2016 Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
1873-4499
Volume :
40
Issue :
6
Database :
MEDLINE
Journal :
Clinical imaging
Publication Type :
Academic Journal
Accession number :
27639863
Full Text :