Back to Search Start Over

Measurement of force sense reproduction in the knee joint: application of a new dynamometric device.

Authors :
Zavieh MK
Amirshakeri B
Rezasoltani A
Talebi GA
Kalantari KK
Nedaey V
Baghban AA
Source :
Journal of physical therapy science [J Phys Ther Sci] 2016 Aug; Vol. 28 (8), pp. 2311-5. Date of Electronic Publication: 2016 Aug 31.
Publication Year :
2016

Abstract

[Purpose] The aim of this study was to determine the reliability of a newly designed dynamometric device for use in frequent force producing/reproducing tasks on the knee joint. [Subjects and Methods] In this cross-sectional study (Development & Reliability), 30 young healthy males and females (age 23.4 ± 2.48 years) were selected among students of Tabriz University of Medical Sciences by simple randomized selection. The study instrument was designed to measure any isometric contraction force exerted by the knee joint flexor/extensor muscles, known as the ipsilateral and contralateral methods. Participant knees were fixed in 60° flexion, and each participant completed the entire set of measurements twice, 72 hours apart. [Results] The findings showed a good intraclass correlation coefficient of 0.73 to 0.81 for all muscle groups. The standard error of measurement and smallest detectable difference for flexor muscle groups were 0.37 and 1.02, respectively, while the values increased to standard error of measurement=0.38 and smallest detectable difference=1.05 for extensor muscle groups. [Conclusion] The device designed could quantify the forces producing/reproducing tasks on the knee joint with a high rate of reliability, and can probably be applied for outcome measurements in proprioceptive assessment of the knee joint.

Details

Language :
English
ISSN :
0915-5287
Volume :
28
Issue :
8
Database :
MEDLINE
Journal :
Journal of physical therapy science
Publication Type :
Academic Journal
Accession number :
27630421
Full Text :
https://doi.org/10.1589/jpts.28.2311