Back to Search Start Over

Field Validation of the ReEBOV Antigen Rapid Test for Point-of-Care Diagnosis of Ebola Virus Infection.

Authors :
Boisen ML
Cross RW
Hartnett JN
Goba A
Momoh M
Fullah M
Gbakie M
Safa S
Fonnie M
Baimba F
Koroma VJ
Geisbert JB
McCormick S
Nelson DK
Millett MM
Oottamasathien D
Jones AB
Pham H
Brown BL
Shaffer JG
Schieffelin JS
Kargbo B
Gbetuwa M
Gevao SM
Wilson RB
Pitts KR
Geisbert TW
Branco LM
Khan SH
Grant DS
Garry RF
Source :
The Journal of infectious diseases [J Infect Dis] 2016 Oct 15; Vol. 214 (suppl 3), pp. S203-S209. Date of Electronic Publication: 2016 Aug 11.
Publication Year :
2016

Abstract

Background: The 2013-2016 West African Ebola virus disease (EVD) epidemic is the largest recorded. Triage on the basis of clinical signs had limited success, and the time to diagnosis by quantitative reverse transcription-polymerase chain reaction (qRT-PCR) could exceed 5 days. Here we describe the development and field validation of the ReEBOV Antigen Rapid Test (ReEBOV RDT) to aid triage of individuals with suspected EVD.<br />Methods: Samples from patients with suspected EVD were submitted to Kenema Government Hospital, Sierra Leone, for Lassa fever and EVD screening throughout 2014. Banked residual clinical samples were tested in November 2014 and January 2015 in a blinded field trial to estimate the clinical effectiveness of the ReEBOV RDT, compared with EBOV-specific qRT-PCR.<br />Results: Preliminary ReEBOV RDT performance demonstrated a positive percentage agreement (PPA) of 91.1% (195 of 214 results; 95% confidence interval [CI], 86.5%-94.6%) and a negative percentage agreement (NPA) of 90.2% (175 of 194; 95% CI, 85.1%-94.0%). The final estimates used by the Food and Drug Administration to determine whether to grant emergency use authorization for the test, which excluded a qRT-PCR reference method threshold cutoff, were a PPA of 62.1% (72 of 116 results; 95% CI, 52.6%-70.9%) and a NPA of 96.7% (58 of 60; 95% CI, 88.5%-99.6%), with a diagnostic likelihood of 18.6. A subsequent, independent evaluation by the World Health Organization generated results consistent with the preliminary performance estimates.<br />Conclusions: The ReEBOV RDT demonstrated the potential to provide clinically effective rapid and accurate point-of-care test results and, thus, to be a powerful tool for increasing triage efficiency.<br /> (© The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.)

Details

Language :
English
ISSN :
1537-6613
Volume :
214
Issue :
suppl 3
Database :
MEDLINE
Journal :
The Journal of infectious diseases
Publication Type :
Academic Journal
Accession number :
27521365
Full Text :
https://doi.org/10.1093/infdis/jiw261