Reference values for the cervical length measurement in the second trimester of pregnancy using the transvaginal ultrasound in a large Brazilian population.
- Source :
-
Obstetrics & gynecology science [Obstet Gynecol Sci] 2016 Jul; Vol. 59 (4), pp. 303-6. Date of Electronic Publication: 2016 Jul 13. - Publication Year :
- 2016
-
Abstract
- To establish reference values for the cervical length (CL) measurement by transvaginal ultrasound between 20 and 24+6 weeks of gestation in a large Brazilian population. A retrospective cross-sectional study was performed with 996 singleton pregnancies. The CL measurement (mm) using the transvaginal ultrasound was obtained in a sagittal view and the calipers positioned to measure the linear distance between the triangular area of echodensity at the external os and the internal os. The median±standard deviation and ranges for the CL measurement (mm) was 37.0±10.7 (range, 8 to 51). CL measurement did not modify significantly with gestational age. The observed percentiles for the CL measurement (mm) considering all number case were the following: 5th, 28 mm; 50th, 37 mm; and 95th, 45 mm. Reference values for the CL measurement by transvaginal ultrasound between 20 and 24+6 weeks of gestation in a large heterogeneous Brazilian population were established.
Details
- Language :
- English
- ISSN :
- 2287-8572
- Volume :
- 59
- Issue :
- 4
- Database :
- MEDLINE
- Journal :
- Obstetrics & gynecology science
- Publication Type :
- Academic Journal
- Accession number :
- 27462597
- Full Text :
- https://doi.org/10.5468/ogs.2016.59.4.303