Back to Search
Start Over
A new nail with a locking blade for complex proximal humeral fractures.
- Source :
-
European journal of orthopaedic surgery & traumatology : orthopedie traumatologie [Eur J Orthop Surg Traumatol] 2016 Dec; Vol. 26 (8), pp. 831-836. Date of Electronic Publication: 2016 Jul 26. - Publication Year :
- 2016
-
Abstract
- Introduction: The objective of this study was to assess the clinical outcome of displaced proximal humerus fracture treated with a new locking blade nail.<br />Materials and Methods: This prospective study included a series of 92 patients with acute fracture of the proximal humerus treated in one hospital level I trauma centre with locking blade nail between December 2010 and December 2013. According to the Neer classification, all fractures were two- to four-part fractures. Age adopted Constant score, DASH and visual analogue scores were used as outcome measures.<br />Results: A total of 92 patients were enrolled in the study. However, 29 patients were excluded due to loss to follow-up and death. Ultimately, 63 patients were available for final follow-up and data analysis. The mean duration of follow-up was 22 months (range 16-48 months). On average at 1 year, all fractures had united. The mean weighted Constant score was 84.2 % and the median disabilities of the arm, shoulder and hand (DASH) score was 26, the range of elevation was 115 and range of abduction was 97. The head shaft angle was 130, and pain visual analogue was 1.6. We found that 5 of the 63 patients (8 %) demonstrated complications. Two patients (3 %) displayed secondary displacement and require device removal. Two patients (3 %) had impingement due to prominent metal work, and one patient had a superficial wound infection which was treated with a course of antibiotics.<br />Conclusion: Our study shows excellent results with new locking blade nail for displaced proximal humerus fractures. We think the locking blade nail offers stiff triangular fixation of the head fragment and support of the medial calcar region to prevent secondary varus collapse.<br />Level of Evidence: III.<br />Competing Interests: Senior author (EM) is a consultant and receives royalties from Marquardt Medizintechnik Europe. The other author (F R H) has no interest, any financial gains, or relationship to any third party relating to this study. Ethical standards This study complies with the current laws of the country in which it was conducted.
- Subjects :
- Aged
Equipment Design
Female
Follow-Up Studies
Fracture Healing
Germany
Humans
Male
Middle Aged
Prospective Studies
Range of Motion, Articular
Recovery of Function
Shoulder Fractures diagnosis
Shoulder Fractures physiopathology
Treatment Outcome
Fracture Dislocation diagnosis
Fracture Dislocation physiopathology
Fracture Dislocation surgery
Fracture Fixation, Internal instrumentation
Fracture Fixation, Internal methods
Humerus diagnostic imaging
Humerus injuries
Nails
Shoulder Fractures surgery
Subjects
Details
- Language :
- English
- ISSN :
- 1432-1068
- Volume :
- 26
- Issue :
- 8
- Database :
- MEDLINE
- Journal :
- European journal of orthopaedic surgery & traumatology : orthopedie traumatologie
- Publication Type :
- Academic Journal
- Accession number :
- 27460360
- Full Text :
- https://doi.org/10.1007/s00590-016-1817-4