Back to Search
Start Over
Investigation of a novel implantable suprachoroidal pressure transducer for telemetric intraocular pressure monitoring.
- Source :
-
Experimental eye research [Exp Eye Res] 2016 Oct; Vol. 151, pp. 54-60. Date of Electronic Publication: 2016 Jul 25. - Publication Year :
- 2016
-
Abstract
- Intraocular Pressure (IOP) is an important and modifiable risk factor for glaucoma progression. IOP fluctuations and spikes often remain undetected despite clinical routine examinations. Therefore telemetric IOP measurement systems with continuous IOP monitoring can provide major advantages in glaucoma surveillance. To the best of our knowledge, this is the first study to investigate implantable telemetric suprachoroidal IOP sensors. Six novel telemetric pressure transducers were implanted in the suprachoroidal space of 6 eyes from 6 New Zealand White rabbits. Functionality of each microsensor was verified 1, 4, 8, 12 and 30 weeks after implantation. After cannulation of the anterior chamber different intracameral pressure levels were generated using a height adjustable water column. Telemetric assessed IOP and intracameral pressure were analysed using scatter plots and Bland-Altman analysis (95% CI). Mean bias (limits of agreement) 1, 4, 8, 12 and 30 weeks after implantation was 0.14 mmHg (-2.04 to 2.31 mmHg), 0.01 mmHg (-2.83 to 2.86 mmHg), 0.62 mmHg (-2.08 to 3.32 mmHg), 0.47 mmHg (-3.04 to 3.98 mmHg) and 0.33 mmHg (-2.75 to 3.42 mmHg) respectively. Ophthalmological examinations showed no signs of conjunctival, scleral, choroidal or retinal lesions. Histological analyses revealed a small band of fibrosis next to the implantation site but showed no signs of inflammation, necrosis or other pathologies. Implantable telemetric suprachoroidal pressure sensors provided promising concordance between telemetric and intracameral IOP values. Clinical and histological examinations revealed good biocompatibility 30 weeks after implantation. A major advantage of the suprachoroidal approach is that the anterior chamber stays unaffected during implantation. Therefore the procedure can be performed regardless of the lens status and any anterior chamber pathologies.<br /> (Copyright © 2016 Elsevier Ltd. All rights reserved.)
- Subjects :
- Animals
Anterior Chamber
Choroid
Equipment Design
Female
Glaucoma, Open-Angle physiopathology
Male
Rabbits
Reproducibility of Results
Biosensing Techniques instrumentation
Glaucoma, Open-Angle diagnosis
Intraocular Pressure physiology
Telemetry instrumentation
Tonometry, Ocular instrumentation
Subjects
Details
- Language :
- English
- ISSN :
- 1096-0007
- Volume :
- 151
- Database :
- MEDLINE
- Journal :
- Experimental eye research
- Publication Type :
- Academic Journal
- Accession number :
- 27456134
- Full Text :
- https://doi.org/10.1016/j.exer.2016.07.016