Back to Search
Start Over
Semi-automatic carotid intraplaque hemorrhage detection and quantification on Magnetization-Prepared Rapid Acquisition Gradient-Echo (MP-RAGE) with optimized threshold selection.
- Source :
-
Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance [J Cardiovasc Magn Reson] 2016 Jul 16; Vol. 18 (1), pp. 41. Date of Electronic Publication: 2016 Jul 16. - Publication Year :
- 2016
-
Abstract
- Background: Intraplaque hemorrhage (IPH) is associated with atherosclerosis progression and subsequent cardiovascular events. We sought to develop a semi-automatic method with an optimized threshold for carotid IPH detection and quantification on MP-RAGE images using matched histology as the gold standard.<br />Methods: Fourteen patients scheduled for carotid endarterectomy underwent 3D MP-RAGE cardiovascular magnetic resonance (CMR) preoperatively. Presence and area of IPH were recorded using histology. Presence and area of IPH were also recorded on CMR based on intensity thresholding using three references for intensity normalization: the sternocleidomastoid muscle (SCM), the adjacent muscle and the automatically generated local median value. The optimized intensity thresholds were obtained by maximizing the Youden's index for IPH detection. Using leave-one-out cross validation, the sensitivity and specificity for IPH detection based on our proposed semi-automatic method and the agreement with histology on IPH area quantification were evaluated.<br />Results: The optimized intensity thresholds for IPH detection were 1.0 times the SCM intensity, 1.6 times the adjacent muscle intensity and 2.2 times the median intensity. Using the semi-automatic method with the optimized intensity threshold, the following IPH detection and quantification performance was obtained: sensitivities up to 59, 68 and 80 %; specificities up to 85, 74 and 79 %; Pearson's correlation coefficients (IPH area measurement) up to 0.76, 0.93 and 0.90, respectively, using SCM, the adjacent muscle and the local median value for intensity normalization, after heavily calcified and small IPH were excluded.<br />Conclusions: A semi-automatic method with good performance on IPH detection and quantification can be obtained in MP-RAGE CMR, using an optimized intensity threshold comparing to the adjacent muscle. The automatically generated reference of local median value provides comparable performance and may be particularly useful for developing automatic classifiers. Use of the SCM intensity as reference is not recommended without coil sensitivity correction when surface coils are used.
- Subjects :
- Aged
Aged, 80 and over
Area Under Curve
Automation
Biopsy
Carotid Arteries pathology
Carotid Artery Diseases pathology
Female
Hemorrhage pathology
Humans
Image Interpretation, Computer-Assisted standards
Magnetic Resonance Imaging standards
Male
Middle Aged
Observer Variation
Predictive Value of Tests
Prognosis
ROC Curve
Reference Standards
Reproducibility of Results
Carotid Arteries diagnostic imaging
Carotid Artery Diseases diagnostic imaging
Hemorrhage diagnostic imaging
Image Interpretation, Computer-Assisted methods
Magnetic Resonance Imaging methods
Plaque, Atherosclerotic
Subjects
Details
- Language :
- English
- ISSN :
- 1532-429X
- Volume :
- 18
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance
- Publication Type :
- Academic Journal
- Accession number :
- 27430263
- Full Text :
- https://doi.org/10.1186/s12968-016-0260-3