Back to Search
Start Over
Liquid Chromatography with a Fluorimetric Detection Method for Analysis of Paralytic Shellfish Toxins and Tetrodotoxin Based on a Porous Graphitic Carbon Column.
- Source :
-
Toxins [Toxins (Basel)] 2016 Jun 28; Vol. 8 (7). Date of Electronic Publication: 2016 Jun 28. - Publication Year :
- 2016
-
Abstract
- Paralytic shellfish toxins (PST) traditionally have been analyzed by liquid chromatography with either pre- or post-column derivatization and always with a silica-based stationary phase. This technique resulted in different methods that need more than one run to analyze the toxins. Furthermore, tetrodotoxin (TTX) was recently found in bivalves of northward locations in Europe due to climate change, so it is important to analyze it along with PST because their signs of toxicity are similar in the bioassay. The methods described here detail a new approach to eliminate different runs, by using a new porous graphitic carbon stationary phase. Firstly we describe the separation of 13 PST that belong to different groups, taking into account the side-chains of substituents, in one single run of less than 30 min with good reproducibility. The method was assayed in four shellfish matrices: mussel (Mytillus galloprovincialis), clam (Pecten maximus), scallop (Ruditapes decussatus) and oyster (Ostrea edulis). The results for all of the parameters studied are provided, and the detection limits for the majority of toxins were improved with regard to previous liquid chromatography methods: the lowest values were those for decarbamoyl-gonyautoxin 2 (dcGTX2) and gonyautoxin 2 (GTX2) in mussel (0.0001 mg saxitoxin (STX)·diHCl kg(-1) for each toxin), decarbamoyl-saxitoxin (dcSTX) in clam (0.0003 mg STX·diHCl kg(-1)), N-sulfocarbamoyl-gonyautoxins 2 and 3 (C1 and C2) in scallop (0.0001 mg STX·diHCl kg(-1) for each toxin) and dcSTX (0.0003 mg STX·diHCl kg(-1) ) in oyster; gonyautoxin 2 (GTX2) showed the highest limit of detection in oyster (0.0366 mg STX·diHCl kg(-1)). Secondly, we propose a modification of the method for the simultaneous analysis of PST and TTX, with some minor changes in the solvent gradient, although the detection limit for TTX does not allow its use nowadays for regulatory purposes.
- Subjects :
- Animals
Chromatography, High Pressure Liquid standards
Limit of Detection
Mytilus chemistry
Ostrea chemistry
Oxidation-Reduction
Pecten chemistry
Pectinidae chemistry
Porosity
Reproducibility of Results
Saxitoxin adverse effects
Saxitoxin analysis
Seafood adverse effects
Tetrodotoxin adverse effects
Bivalvia chemistry
Chromatography, High Pressure Liquid instrumentation
Fluorometry standards
Food Contamination
Graphite chemistry
Paralysis chemically induced
Saxitoxin analogs & derivatives
Seafood analysis
Shellfish Poisoning
Tetrodotoxin analysis
Subjects
Details
- Language :
- English
- ISSN :
- 2072-6651
- Volume :
- 8
- Issue :
- 7
- Database :
- MEDLINE
- Journal :
- Toxins
- Publication Type :
- Academic Journal
- Accession number :
- 27367728
- Full Text :
- https://doi.org/10.3390/toxins8070196