Back to Search Start Over

Laparoscopic detection and resection of occult liver tumors of multiple cancer types using real-time near-infrared fluorescence guidance.

Authors :
Boogerd LS
Handgraaf HJ
Lam HD
Huurman VA
Farina-Sarasqueta A
Frangioni JV
van de Velde CJ
Braat AE
Vahrmeijer AL
Source :
Surgical endoscopy [Surg Endosc] 2017 Feb; Vol. 31 (2), pp. 952-961. Date of Electronic Publication: 2016 Jun 29.
Publication Year :
2017

Abstract

Background: Tumor recurrence after radical resection of hepatic tumors is not uncommon, suggesting that malignant lesions are missed during surgery. Intraoperative navigation using fluorescence guidance is an innovative technique enabling real-time identification of (sub)capsular liver tumors. The objective of the current study was to compare fluorescence imaging (FI) and conventional imaging modalities for laparoscopic detection of both primary and metastatic tumors in the liver.<br />Methods: Patients undergoing laparoscopic resection of a malignant hepatic tumor were eligible for inclusion. Patients received standard of care, including preoperative CT and/or MRI. In addition, 10 mg indocyanine green was intravenously administered 1 day prior to surgery. After introduction of the laparoscope, inspection, FI, and laparoscopic ultrasonography (LUS) were performed. Histopathological examination of resected suspect tissue was considered the gold standard.<br />Results: Twenty-two patients suspected of having hepatocellular carcinoma (n = 4), cholangiocarcinoma (n = 2) or liver metastases from colorectal carcinoma (n = 12), uveal melanoma (n = 2), and breast cancer (n = 2) were included. Two patients were excluded because their surgery was unexpectedly postponed several days. Twenty-six malignancies were resected in the remaining 20 patients. Sensitivity for various modalities was 80 % (CT), 84 % (MRI), 62 % (inspection), 86 % (LUS), and 92 % (FI), respectively. Three metastases (12 %) were identified solely by FI. All 26 malignancies could be detected by combining LUS and FI (100 % sensitivity).<br />Conclusion: This study demonstrates added value of FI during laparoscopic resections of several hepatic tumors. Although larger series will be needed to confirm long-term patient outcome, the technology already aids the surgeon by providing real-time fluorescence guidance.<br />Competing Interests: Compliance with ethical standardsDisclosuresDr. Frangioni is CEO of Curadel, LLC, a for-profit company that has licensed FLARE® technology from the Beth Israel Deaconess Medical Center. Drs. Boogerd, Drs. Handgraaf, Drs. Lam, Dr. Huurman, Dr. Farina-Sarasqueta, Dr. van de Velde, Dr. Braat, and Dr. Vahrmeijer have no conflicts of interest or financial ties to disclose.

Details

Language :
English
ISSN :
1432-2218
Volume :
31
Issue :
2
Database :
MEDLINE
Journal :
Surgical endoscopy
Publication Type :
Academic Journal
Accession number :
27357928
Full Text :
https://doi.org/10.1007/s00464-016-5007-6