Back to Search
Start Over
Pigtail assisted tracking of guide catheter for navigating the difficult radial: Overcoming the "razor effect".
- Source :
-
Indian heart journal [Indian Heart J] 2016 May-Jun; Vol. 68 (3), pp. 355-60. Date of Electronic Publication: 2016 Mar 26. - Publication Year :
- 2016
-
Abstract
- During transradial procedures, sharp edge of the guide catheter tip may act like a "razor-blade" and can prevent the catheter navigation. It is especially common with radial artery loop, tortuous radial artery and radial artery spasm. We describe a cost effective and easy technique which overcomes this "razor-blade" effect and helps in tracking the guide catheter in complex radial anatomy for the easy and successful completion of procedure.<br /> (Copyright © 2016. Published by Elsevier B.V.)
Details
- Language :
- English
- ISSN :
- 2213-3763
- Volume :
- 68
- Issue :
- 3
- Database :
- MEDLINE
- Journal :
- Indian heart journal
- Publication Type :
- Report
- Accession number :
- 27316490
- Full Text :
- https://doi.org/10.1016/j.ihj.2016.03.016