Back to Search Start Over

Even the Intraoperative Knowledge of Femoral Stem Anteversion Cannot Prevent Impingement in Total Hip Arthroplasty.

Authors :
Weber M
Woerner ML
Sendtner E
Völlner F
Grifka J
Renkawitz TF
Source :
The Journal of arthroplasty [J Arthroplasty] 2016 Nov; Vol. 31 (11), pp. 2514-2519. Date of Electronic Publication: 2016 Apr 30.
Publication Year :
2016

Abstract

Background: In this prospective study of 66 patients undergoing cementless total hip arthroplasty through a minimally invasive anterolateral approach, we evaluated the impact of an intraoperative hybrid combined anteversion technique on postoperative range of motion (ROM).<br />Methods: After navigation of femoral stem anteversion, trial acetabular components were positioned manually, and their position recorded with navigation. Then, final components were implanted with navigation at the goals prescribed by the femur-first impingement detection algorithm. Postoperatively, three-dimensional computed tomographies were performed to determine achieved component position and model impingement-free ROM by virtual hip movement, which was compared with published values necessary for activities of daily living. This model was run a second time with the implants in the position selected by the surgeon rather than the navigation program. In addition, we researched into risk factors for ROM differences between the freehand and navigated cup position.<br />Results: We found a lower flexion of 8.3° (8.8°, P < .001) and lower internal rotation of 9.2° (9.5°, P < .001) for the freehand implanted cups in contrast to a higher extension of 9.8° (11.8°, P < .001) compared with the navigation-guided technique. For activities of daily living, 58.9% (33/56) in the freehand group compared with 85.7% (48/56) in the navigation group showed free flexion (P < .001) and similarly 50.0% (28/56) compared with 76.8% (43/56) free internal rotation (P < .001). Body mass index, incision length, and cup size were identified as independent risk factors for reduced flexion and internal rotation in the freehand group.<br />Conclusion: For implementation of a combined anteversion algorithm, intraoperative alignment guides for accurate cup positioning are required using a minimally invasive anterolateral approach. Obese patients are especially at risk of cup malpositioning.<br /> (Copyright © 2016 Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
1532-8406
Volume :
31
Issue :
11
Database :
MEDLINE
Journal :
The Journal of arthroplasty
Publication Type :
Academic Journal
Accession number :
27236745
Full Text :
https://doi.org/10.1016/j.arth.2016.04.024