Back to Search
Start Over
Automatic detection of aorto-femoral vessel trajectory from whole-body computed tomography angiography data sets.
- Source :
-
The international journal of cardiovascular imaging [Int J Cardiovasc Imaging] 2016 Aug; Vol. 32 (8), pp. 1311-22. Date of Electronic Publication: 2016 May 21. - Publication Year :
- 2016
-
Abstract
- Extraction of the aorto-femoral vessel trajectory is important to utilize computed tomography angiography (CTA) in an integrated workflow of the image-guided work-up prior to trans-catheter aortic valve replacement (TAVR). The aim of this study was to develop a new, fully-automated technique for the extraction of the entire arterial access route from the femoral artery to the aortic root. An automatic vessel tracking algorithm was first used to find the centerline that connected the femoral accessing points and the aortic root. Subsequently, a deformable 3D-model fitting method was used to delineate the lumen boundary of the vascular trajectory in the whole-body CTA dataset. A validation was carried out by comparing the automatically obtained results with semi-automatically obtained results from two experienced observers. The whole framework was validated on whole body CTA datasets of 36 patients. The average Dice similarity indexes between the segmentations of the automatic method and observer 1 for the left ilio-femoral artery, the right ilio-femoral artery and the aorta were 0.977 ± 0.030, 0.980 ± 0.019, 0.982 ± 0.016; the average Dice similarity indexes between the segmentations of the automatic method and observer 2 were 0.950 ± 0.040, 0.954 ± 0.031 and 0.965 ± 0.019, respectively. The inter-observer variability resulted in a Dice similarity index of 0.954 ± 0.038, 0.952 ± 0.031 and 0.969 ± 0.018 for the left ilio-femoral artery, the right ilio-femoral artery and the aorta. The average minimal luminal diameters (MLDs) of the ilio-femoral artery were 6.03 ± 1.48, 5.70 ± 1.43 and 5.52 ± 1.32 mm for the automatic method, observer 1 and observer 2 respectively. The MLDs of the aorta were 13.43 ± 2.54, 12.40 ± 2.93 and 12.08 ± 2.40 mm for the automatic method, observer 1 and observer 2 respectively. The automatic measurement overestimated the MLD slightly in the ilio-femoral artery at the average by 0.323 mm (SD = 0.49 mm, p < 0.001) compared to observer 1 and by 0.51 mm (SD = 0.71 mm, p < 0.001) compared to observer 2. The proposed segmentation approach can automatically provide reliable measurements of the entire arterial accessing route that can be used to support TAVR procedures. To the best of our knowledges, this approach is the first fully automatic segmentation method of the whole aorto-femoral vessel trajectory in CTA images.
- Subjects :
- Aged
Aged, 80 and over
Algorithms
Aortic Valve diagnostic imaging
Automation
Cardiac Catheterization methods
Female
Heart Valve Prosthesis Implantation methods
Humans
Imaging, Three-Dimensional
Male
Middle Aged
Models, Cardiovascular
Observer Variation
Patient-Specific Modeling
Predictive Value of Tests
Reproducibility of Results
Retrospective Studies
Workflow
Aorta diagnostic imaging
Computed Tomography Angiography methods
Femoral Artery diagnostic imaging
Iliac Artery diagnostic imaging
Radiographic Image Interpretation, Computer-Assisted methods
Whole Body Imaging methods
Subjects
Details
- Language :
- English
- ISSN :
- 1875-8312
- Volume :
- 32
- Issue :
- 8
- Database :
- MEDLINE
- Journal :
- The international journal of cardiovascular imaging
- Publication Type :
- Academic Journal
- Accession number :
- 27209285
- Full Text :
- https://doi.org/10.1007/s10554-016-0901-5