Back to Search Start Over

An ultra-high performance liquid chromatography-tandem mass spectrometric assay for quantifying 3-ketocholanoic acid: Application to the human liver microsomal CYP3A-dependent lithocholic acid 3-oxidation assay.

Authors :
Bansal S
Chai SF
Lau AJ
Source :
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences [J Chromatogr B Analyt Technol Biomed Life Sci] 2016 Jun 15; Vol. 1023-1024, pp. 1-8. Date of Electronic Publication: 2016 Apr 27.
Publication Year :
2016

Abstract

Lithocholic acid (LCA), a hepatotoxic and carcinogenic bile acid, is metabolized to 3-ketocholanoic acid (3-KCA) by cytochrome P450 3A (CYP3A). In the present study, the objectives were to develop and validate an ultra-high performance liquid chromatography-tandem mass spectrometric (UPLC-MS/MS) method to quantify 3-KCA and apply it to the human liver microsomal CYP3A-dependent LCA 3-oxidation assay. Chromatographic separation was achieved on a Waters ACQUITY™ UPLC C18 column (50×2.1mm, 1.7μm) with a gradient system consisting of 0.1% v/v formic acid in water (solvent A) and 0.1% v/v formic acid in acetonitrile (solvent B). The retention time was 3.73min for 3-KCA and 2.73min for cortisol (internal standard). Positive electrospray ionization with multiple reaction monitoring (MRM) mode was used to quantify 3-KCA (m/z 375.4→135.2) and cortisol (m/z 363.5→121.0). The limit of detection of 3-KCA was 10μM, the lower limit of quantification was 33.3μM, and the calibration curve was linear from 0.05-10μM with r(2)>0.99. Intra-day and inter-day accuracy and precision were <13.7%. The quality control samples were stable when assessed after 4h at room temperature, 24h at 4°C, 14days at -20°C, and three freeze-thaw cycles. The liver microsomal matrix did not affect 3-KCA quantification. The amount of KCA formed in the human liver microsomal LCA 3-oxidation assay was linear with respect to the amount of microsomal protein (up to 40μg) and incubation time (5-30min). Enzyme kinetics experiment indicated that LCA 3-oxidation followed the Michaelis-Menten model with an apparent Km of 26±7μM and Vmax of 303±50pmol/min/mg protein. This novel UPLC-MS/MS method for quantifying 3-KCA offers a specific, sensitive, and fast approach to determine liver microsomal LCA 3-oxidation.<br /> (Copyright © 2016 Elsevier B.V. All rights reserved.)

Details

Language :
English
ISSN :
1873-376X
Volume :
1023-1024
Database :
MEDLINE
Journal :
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences
Publication Type :
Academic Journal
Accession number :
27153105
Full Text :
https://doi.org/10.1016/j.jchromb.2016.04.039