Back to Search
Start Over
Automated replication of cone beam CT-guided treatments in the Pinnacle(3) treatment planning system for adaptive radiotherapy.
- Source :
-
Journal of medical radiation sciences [J Med Radiat Sci] 2016 Mar; Vol. 63 (1), pp. 48-58. Date of Electronic Publication: 2015 Oct 03. - Publication Year :
- 2016
-
Abstract
- Introduction: Time-consuming manual methods have been required to register cone-beam computed tomography (CBCT) images with plans in the Pinnacle(3) treatment planning system in order to replicate delivered treatments for adaptive radiotherapy. These methods rely on fiducial marker (FM) placement during CBCT acquisition or the image mid-point to localise the image isocentre. A quality assurance study was conducted to validate an automated CBCT-plan registration method utilising the Digital Imaging and Communications in Medicine (DICOM) Structure Set (RS) and Spatial Registration (RE) files created during online image-guided radiotherapy (IGRT).<br />Methods: CBCTs of a phantom were acquired with FMs and predetermined setup errors using various online IGRT workflows. The CBCTs, DICOM RS and RE files were imported into Pinnacle(3) plans of the phantom and the resulting automated CBCT-plan registrations were compared to existing manual methods. A clinical protocol for the automated method was subsequently developed and tested retrospectively using CBCTs and plans for six bladder patients.<br />Results: The automated CBCT-plan registration method was successfully applied to thirty-four phantom CBCT images acquired with an online 0 mm action level workflow. Ten CBCTs acquired with other IGRT workflows required manual workarounds. This was addressed during the development and testing of the clinical protocol using twenty-eight patient CBCTs. The automated CBCT-plan registrations were instantaneous, replicating delivered treatments in Pinnacle(3) with errors of ±0.5 mm. These errors were comparable to mid-point-dependant manual registrations but superior to FM-dependant manual registrations.<br />Conclusion: The automated CBCT-plan registration method quickly and reliably replicates delivered treatments in Pinnacle(3) for adaptive radiotherapy.
- Subjects :
- Clinical Protocols
Humans
Phantoms, Imaging
Radiosurgery standards
Radiotherapy Planning, Computer-Assisted standards
Radiotherapy Setup Errors prevention & control
Radiotherapy, Image-Guided standards
Cone-Beam Computed Tomography
Radiosurgery methods
Radiotherapy Planning, Computer-Assisted methods
Radiotherapy, Image-Guided methods
Urinary Bladder Neoplasms radiotherapy
Subjects
Details
- Language :
- English
- ISSN :
- 2051-3909
- Volume :
- 63
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- Journal of medical radiation sciences
- Publication Type :
- Academic Journal
- Accession number :
- 27087975
- Full Text :
- https://doi.org/10.1002/jmrs.141