Back to Search Start Over

Dissolution, dislocation and dimensional changes of endodontic sealers after a solubility challenge: a micro-CT approach.

Authors :
Silva EJ
Perez R
Valentim RM
Belladonna FG
De-Deus GA
Lima IC
Neves AA
Source :
International endodontic journal [Int Endod J] 2017 Apr; Vol. 50 (4), pp. 407-414. Date of Electronic Publication: 2016 Apr 17.
Publication Year :
2017

Abstract

Aim: To evaluate, using a novel micro-CT approach, the solubility and dimensional changes of an MTA-based sealer inside the root canal system after a solubility challenge. The MTA-based material (MTA Fillapex) was compared to a gold standard epoxy-based endodontic sealer (AH Plus).<br />Methodology: Ten human mandibular premolars with a single canal were divided randomly into two groups (n = 5) according to the sealer used. The canals were instrumented using the Reciproc System (VDW) with a R40 file and filled with R40 gutta-percha cones and one of the sealers. The filled canals were immediately scanned in a micro-CT, and after that, the teeth were immersed in 20 mL phosphate-buffered saline (PBS) at 37 °C for 7 days, when they were removed and rescanned. Final image stacks were registered against the initial stacks and the numerical difference between the initial and final volume of the filling material was obtained. Calculations were performed to identify dimensional changes of the filling material. All image stacks were 3D rendered to disclose areas of dislocation of the filling material inside or outside the root canal. The Shapiro-Wilk's test revealed that data were normally distributed; thus, the Student's t-test was used to detect statistically significant changes, assuming a 5% α-error.<br />Results: No significant changes were seen for the percentage volume of material lost after the solubility challenge for both AH Plus and MTA Fillapex groups (1.44% and 1.16%, respectively). A significant difference was, however, found for the volume of filling material which revealed dimensional changes after the solubility test (6.68% for MTA Fillapex and 1.09% for AH Plus). In fact, observation of 3D models disclosed that MTA Fillapex was associated with material extrusion through the foramen in all but one sample. In AH Plus filled samples, no material extrusion was detected.<br />Conclusions: Although the solubility of both sealers was similar using this novel micro-CT approach, MTA Fillapex was associated with significant dimensional changes related to material extrusion through the apex after PBS storage compared to AH Plus.<br /> (© 2016 International Endodontic Journal. Published by John Wiley & Sons Ltd.)

Details

Language :
English
ISSN :
1365-2591
Volume :
50
Issue :
4
Database :
MEDLINE
Journal :
International endodontic journal
Publication Type :
Academic Journal
Accession number :
27000665
Full Text :
https://doi.org/10.1111/iej.12636