Back to Search Start Over

Development and validation of a liquid chromatography-tandem mass spectrometric assay for quantitative analyses of triptans in hair.

Authors :
Vandelli D
Palazzoli F
Verri P
Rustichelli C
Marchesi F
Ferrari A
Baraldi C
Giuliani E
Licata M
Silingardi E
Source :
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences [J Chromatogr B Analyt Technol Biomed Life Sci] 2016 Apr 01; Vol. 1017-1018, pp. 136-144. Date of Electronic Publication: 2016 Feb 27.
Publication Year :
2016

Abstract

Triptans are specific drugs widely used for acute treatment of migraine, being selective 5HT1B/1D receptor agonists. A proper assumption of triptans is very important for an effective treatment; nevertheless patients often underuse, misuse, overuse or use triptans inconsistently, i.e., not following the prescribed therapy. Drug analysis in hair can represent a powerful tool for monitoring the compliance of the patient to the therapy, since it can greatly increase the time-window of detection compared to analyses in biological fluids, such as plasma or urine. In the present study, a liquid chromatography-tandem mass spectrometric (LC-MS/MS) method has been developed and validated for the quantitative analysis in human hair of five triptans commonly prescribed in Italy: almotriptan (AL), eletriptan (EP), rizatriptan (RIZ), sumatriptan (SUM) and zolmitriptan (ZP). Hair samples were decontaminated and incubated overnight in diluted hydrochloric acid; the extracts were purified by mixed-mode SPE cartridges and analyzed by LC-MS/MS under gradient elution in positive multiple reaction monitoring (MRM) mode. The procedure was fully validated in terms of selectivity, linearity, limit of detection (LOD) and lower limit of quantitation (LLOQ), accuracy, precision, carry-over, recovery, matrix effect and dilution integrity. The method was linear in the range 10-1000pg/mg hair, with R(2) values of at least 0.990; the validated LLOQ values were in the range 5-7pg/mg hair. The method offered satisfactory precision (RSD <10%), accuracy (90-110%) and recovery (>85%) values. The validated procedure was applied on 147 authentic hair samples from subjects being treated in the Headache Centre of Modena University Hospital in order to verify the possibility of monitoring the corresponding hair levels for the taken triptans.<br /> (Copyright © 2016 Elsevier B.V. All rights reserved.)

Details

Language :
English
ISSN :
1873-376X
Volume :
1017-1018
Database :
MEDLINE
Journal :
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences
Publication Type :
Academic Journal
Accession number :
26970848
Full Text :
https://doi.org/10.1016/j.jchromb.2016.02.031