Modification to the accelerator of the NBI-1B ion source for improving the injection efficiency.

Authors :
Kim TS
Jeong SH
Chang DH
In SR
Park M
Jung BK
Lee KW
Wang SJ
Bae YS
Park HT
Kim JS
Cho W
Choi DJ
Source :
The Review of scientific instruments [Rev Sci Instrum] 2016 Feb; Vol. 87 (2), pp. 02B317.
Publication Year :
2016

Abstract

Minimizing power loss of a neutral beam imposes modification of the accelerator of the ion source for further improvement of the beam optics. The beam optics can be improved by focusing beamlets. The injection efficiencies by the steering of ion beamlets are investigated numerically to find the optimum modification of the accelerator design of the NBI-1B ion source. The beam power loss was reduced by aperture displacement of three edge beamlets arrays considering power loadings on the beamline components. Successful testing and operation of the ion source at 60 keV/84% of injection efficiency led to the possibility of enhancing the system capability to a 2.4 MW power level at 100 keV/1.9 μP.