Temperature effects of Mach-Zehnder interferometer using a liquid crystal-filled fiber.

Authors :
Ho BY
Su HP
Tseng YP
Wu ST
Hwang SJ
Source :
Optics express [Opt Express] 2015 Dec 28; Vol. 23 (26), pp. 33588-96.
Publication Year :
2015

Abstract

We demonstrated a simple and cost-effective method to fabricate all fiber Mach-Zehnder interferometer (MZI) based on cascading a short section of liquid crystal (LC)-filled hollow-optic fiber (HOF) between two single mode fibers by using automatically splicing technique. The transmission spectra of the proposed MZI with different LC-infiltrated length were measured and the temperature-induced wavelength shifts of the interference fringes were recorded. Both blue shift and red shift were observed, depending the temperature range. Based on our experimental results, interference fringe was observed with a maximum interferometric contrast over 35dB. The temperature-induced resonant wavelength blue-shifts 70.4 nm for the MZI with an LC length of 9.79 mm and the wavelength temperature sensitivity of -1.55 nm/°C is easily achieved as the temperature increases from 25°C to 77°C.

Details

Language :
English
ISSN :
1094-4087
Volume :
23
Issue :
26
Database :
MEDLINE
Journal :
Optics express
Publication Type :
Academic Journal
Accession number :
26832023
Full Text :
https://doi.org/10.1364/OE.23.033588