Back to Search Start Over

Automatic Measurement of the Myocardial Interstitium: Synthetic Extracellular Volume Quantification Without Hematocrit Sampling.

Authors :
Treibel TA
Fontana M
Maestrini V
Castelletti S
Rosmini S
Simpson J
Nasis A
Bhuva AN
Bulluck H
Abdel-Gadir A
White SK
Manisty C
Spottiswoode BS
Wong TC
Piechnik SK
Kellman P
Robson MD
Schelbert EB
Moon JC
Source :
JACC. Cardiovascular imaging [JACC Cardiovasc Imaging] 2016 Jan; Vol. 9 (1), pp. 54-63.
Publication Year :
2016

Abstract

Objectives: The authors sought to generate a synthetic extracellular volume fraction (ECV) from the relationship between hematocrit and longitudinal relaxation rate of blood.<br />Background: ECV quantification by cardiac magnetic resonance (CMR) measures diagnostically and prognostically relevant changes in the extracellular space. Current methodologies require blood hematocrit (Hct) measurement-a complication to easy clinical application. We hypothesized that the relationship between Hct and longitudinal relaxation rate of blood (R1 = 1/T1blood) could be calibrated and used to generate a synthetic ECV without Hct that was valid, user-friendly, and prognostic.<br />Methods: Proof-of-concept: 427 subjects with a wide range of health and disease were divided into derivation (n = 214) and validation (n = 213) cohorts. Histology cohort: 18 patients with severe aortic stenosis with histology obtained during valve replacement. Outcome cohort: For comparison with external outcome data, we applied synthetic ECV to 1,172 consecutive patients (median follow-up 1.7 years; 74 deaths). All underwent CMR scanning at 1.5-T with ECV calculation from pre- and post-contrast T1 (blood and myocardium) and venous Hct.<br />Results: Proof-of-concept: In the derivation cohort, native R1blood and Hct showed a linear relationship (R(2) = 0.51; p < 0.001), which was used to create synthetic Hct and ECV. Synthetic ECV correlated well with conventional ECV (R(2) = 0.97; p < 0.001) without bias. These results were maintained in the validation cohort. Histology cohort: Synthetic and conventional ECV both correlated well with collagen volume fraction measured from histology (R(2) = 0.61 and 0.69, both p < 0.001) with no statistical difference (p = 0.70). Outcome cohort: Synthetic ECV related to all-cause mortality (hazard ratio 1.90; 95% confidence interval 1.55 to 2.31; for every 5% increase in ECV). Finally, we engineered a synthetic ECV tool, generating automatic ECV maps during image acquisition.<br />Conclusions: Synthetic ECV provides validated noninvasive quantification of the myocardial extracellular space without blood sampling and is associated with cardiovascular outcomes.<br /> (Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
1876-7591
Volume :
9
Issue :
1
Database :
MEDLINE
Journal :
JACC. Cardiovascular imaging
Publication Type :
Academic Journal
Accession number :
26762875
Full Text :
https://doi.org/10.1016/j.jcmg.2015.11.008