Back to Search Start Over

Outcome of paroxysmal atrial fibrillation ablation with the cryoballoon using two different application times: the 4- versus 3-min protocol.

Authors :
Straube F
Dorwarth U
Hartl S
Bunz B
Wankerl M
Ebersberger U
Hoffmann E
Source :
Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing [J Interv Card Electrophysiol] 2016 Mar; Vol. 45 (2), pp. 169-77. Date of Electronic Publication: 2015 Dec 23.
Publication Year :
2016

Abstract

Purpose: The second-generation cryoballoon (CBG2) is highly effective for pulmonary vein isolation (PVI) in paroxysmal atrial fibrillation (PAF). One-year outcome data are consistent among different research groups. First results suggest that a shortened application time might be equally effective. The objective of the study was to compare procedural and outcome data for a 240 and 180-s protocol.<br />Methods: Prospectively, consecutive patients with symptomatic PAF underwent initial PVI with CBG2. In succession, two groups were created: the application time was 240 s in group 1 and 180 s in group 2. In both groups, a bonus application was applied. Periprocedural data, complications, and freedom from atrial fibrillation (AF)/AT/symptoms were compared between the groups.<br />Results: From May 2012 to June 2013, 114 patients (57 per group, 38% female) were included. The mean left atrial dwelling time decreased by 19 min (-16%) in group 2 compared to group 1 (p = 0.005). Intraprocedural pulmonary vein (PV) reconduction occurred infrequently (0.4% in both groups, p = 1.0). One persistent PNP occurred and resolved during the follow-up. Complications were without significant differences. One patient was lost to follow-up. The cumulative rates of freedom from recurrence at 12 months are 76.8% in group 1 and 83.6% in group 2. After a mean follow-up of 491 ± 208 days, the rates of freedom from AF/AT/symptoms at last visit were 38/57 (67%) and 44/56 (78.6%) in groups 1 and 2 (p = 0.14), respectively. Female sex was identified as a predictor for recurrence.<br />Conclusions: Compared to a protocol with cryoballoon applications of 240 s, a shortened application time to 180 s results in a faster procedure with comparable high rates of freedom from AF at 16 months. Female sex seems to be predictive for recurrences; this finding has to be reconfirmed in a larger population.

Details

Language :
English
ISSN :
1572-8595
Volume :
45
Issue :
2
Database :
MEDLINE
Journal :
Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing
Publication Type :
Academic Journal
Accession number :
26698157
Full Text :
https://doi.org/10.1007/s10840-015-0084-3