Back to Search
Start Over
Positron emission mammography in the diagnosis of breast cancer. Is maximum PEM uptake value a valuable threshold for malignant breast cancer detection?
- Source :
-
Nuklearmedizin. Nuclear medicine [Nuklearmedizin] 2016; Vol. 55 (1), pp. 15-20. Date of Electronic Publication: 2015 Dec 02. - Publication Year :
- 2016
-
Abstract
- Aim: To evaluate the diagnostic value (sensitivity, specificity) of positron emission mammography (PEM) in a single site non-interventional study using the maximum PEM uptake value (PUVmax).<br />Patients, Methods: In a singlesite, non-interventional study, 108 patients (107 women, 1 man) with a total of 151 suspected lesions were scanned with a PEM Flex Solo II (Naviscan) at 90 min p.i. with 3.5 MBq 18F-FDG per kg of body weight. In this ROI(region of interest)-based analysis, maximum PEM uptake value (PUV) was determined in lesions, tumours (PUVmaxtumour), benign lesions (PUVmaxnormal breast) and also in healthy tissues on the contralateral side (PUVmaxcontralateral breast). These values were compared and contrasted. In addition, the ratios of PUVmaxtumour / PUVmaxcontralateral breast and PUVmaxnormal breast / PUVmaxcontralateral breast were compared. The image data were interpreted independently by two experienced nuclear medicine physicians and compared with histology in cases of suspected carcinoma.<br />Results: Based on a criteria of PUV>1.9, 31 out of 151 lesions in the patient cohort were found to be malignant (21%). A mean PUVmaxtumour of 3.78 ± 2.47 was identified in malignant tumours, while a mean PUVmaxnormal breast of 1.17 ± 0.37 was reported in the glandular tissue of the healthy breast, with the difference being statistically significant (p < 0.001). Similarly, the mean ratio between tumour and healthy glandular tissue in breast cancer patients (3.15 ± 1.58) was found to be significantly higher than the ratio for benign lesions (1.17 ± 0.41, p < 0.001).<br />Conclusion: PEM is capable of differentiating breast tumours from benign lesions with 100% sensitivity along with a high specificity of 96%, when a threshold of PUVmax >1.9 is applied.
- Subjects :
- Adult
Aged
Aged, 80 and over
Female
Humans
Image Enhancement methods
Male
Middle Aged
Reproducibility of Results
Sensitivity and Specificity
Young Adult
Algorithms
Breast Neoplasms diagnostic imaging
Image Interpretation, Computer-Assisted methods
Mammography methods
Positron-Emission Tomography methods
Subjects
Details
- Language :
- English
- ISSN :
- 2567-6407
- Volume :
- 55
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- Nuklearmedizin. Nuclear medicine
- Publication Type :
- Academic Journal
- Accession number :
- 26627876
- Full Text :
- https://doi.org/10.3413/Nukmed-0753-15-07