Back to Search Start Over

Radiation Dose Survey for Common Computed Tomography Exams: 2013 British Columbia Results.

Authors :
Thakur Y
Bjarnason TA
Baxter P
Griffith M
Eaton K
Source :
Canadian Association of Radiologists journal = Journal l'Association canadienne des radiologistes [Can Assoc Radiol J] 2016 Feb; Vol. 67 (1), pp. 88-95. Date of Electronic Publication: 2015 Nov 19.
Publication Year :
2016

Abstract

In 2013 Health Canada conducted a national survey of computed tomography (CT) radiation usage. We analysed contributions from all 7 public health authorities in the province of British Columbia, which covered scanner age, number of slices, and common adult protocols (≥ 19 years: 70 ± 20 kg, head, chest, abdomen/pelvis, and trunk). Patient doses were recorded for common protocols. Diagnostic reference levels (DRLs) was calculated using scanner data with >10 patient doses recorded for each protocol. Data was analysed based on image reconstruction (filtered backprojection vs iterative reconstruction [IR] vs IR available but not in use). Provincial response was 92%, with 59 of 64 CT data used for analysis. The average scanner age was 5.5 years old, with 39% of scanners installed between 2008-2013; 78.5% of scanners were multislice (>64 slices), and 44% of scanners had IR available. Overall British Columbia DRLs were: head = 1305, chest = 529, abdomen/pelvis = 819, and trunk = 1225. DRLs were consistent with Health Canada recommendations and other Canadian published values, but above international standards. For sites with IR available, less than 50% used this technology routinely for head, chest and trunk exams. Overall, use of IR reduced radiation usage between 11%-32% compared to filtered backprojection, while sites using IR vs IR available used 30%/43% less radiation for head/chest exams (P < .05). No significant difference was observed for abdomen/pelvis exams (P = .385). With the fast pace of CT technical advancement, DRLs should reflect the technology used, instead of just globally applied to anatomical regions. Federal guidelines should be updated at a higher frequency to reflect new technology. In addition, new technologies must be utilised to optimize image quality vs radiation usage.<br /> (Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
1488-2361
Volume :
67
Issue :
1
Database :
MEDLINE
Journal :
Canadian Association of Radiologists journal = Journal l'Association canadienne des radiologistes
Publication Type :
Academic Journal
Accession number :
26608253
Full Text :
https://doi.org/10.1016/j.carj.2015.07.002