Back to Search Start Over

Outcomes of biodegradable polymer sirolimus-eluting PROLIM stent in patients with coronary artery disease. Results of 12-month follow-up of prospective registry.

Authors :
Roleder T
Smolka G
Podolecka E
Chudek J
Dworowy S
Żelazowska K
Wojakowski W
Ochała A
Source :
Kardiologia polska [Kardiol Pol] 2016; Vol. 74 (5), pp. 411-7. Date of Electronic Publication: 2015 Oct 27.
Publication Year :
2016

Abstract

Background: Data from clinical trials suggested that biodegradable-polymer-based drug-eluting stents (DES) might improve long-term clinical outcomes. PROLIM (Balton, Warsaw, Poland) DES is based on a stainless steel platform with a closed cell design releasing sirolimus from biodegradable copolymer (lactic and glycolic acid) in eight weeks.<br />Aim: In the present study the safety and the efficacy of a PROLIM stent was assessed in patients with de novo coronary lesions in 12-month clinical follow-up.<br />Methods: It was a single-centre, observational, prospective registry to assess the safety and efficacy of a PROLIM stent implantation in all consecutive patients with de novo coronary artery lesions treated with percutaneous coronary intervention (PCI). The primary study endpoint was a composite safety (cardiac death, non-fatal myocardial infarction), and the second study endpoint was the efficacy of PROLIM implantation-clinically driven target vessel revascularisation (TVR) assessed at 12-month follow-up.<br />Results: One hundred patients were enrolled into the study and 118 PROLIM stents were implanted. Thirty-two (32%) patients had diabetes, 46 (46%) patients were prior PCI, and 17 (17%) patients had coronary artery bypass grafting. 67% of stented lesions were complex ones (B2/C) and 17% were bifurcations. During the 12-month follow-up primary study endpoints occurred in five (5%) patients. Two (2%) cardiac deaths were reported and three (3%) TVRs were performed, of which one was related to in-PROLIM stent restenosis.<br />Conclusions: PCI with biodegradable-polymer PROLIM DES seems to be safe and effective in 12-month follow-up. A larger trial is warranted to assess clinical outcomes post PROLIM stent implantation.

Details

Language :
English
ISSN :
1897-4279
Volume :
74
Issue :
5
Database :
MEDLINE
Journal :
Kardiologia polska
Publication Type :
Academic Journal
Accession number :
26502940
Full Text :
https://doi.org/10.5603/KP.a2015.0208