Back to Search Start Over

Corneal Deformation Response and Ocular Geometry: A Noninvasive Diagnostic Strategy in Marfan Syndrome.

Authors :
Beene LC
Traboulsi EI
Seven I
Ford MR
Sinha Roy A
Butler RS
Dupps WJ Jr
Source :
American journal of ophthalmology [Am J Ophthalmol] 2016 Jan; Vol. 161, pp. 56-64.e1. Date of Electronic Publication: 2015 Oct 24.
Publication Year :
2016

Abstract

Purpose: To evaluate corneal air-puff deformation responses and ocular geometry as predictors of Marfan syndrome.<br />Design: Prospective observational clinical study.<br />Methods: Sixteen investigator-derived, 4 standard Ocular Response Analyzer (ORA), and geometric variables from corneal tomography and optical biometry using Oculus Pentacam and IOL Master were assessed for discriminative value in Marfan syndrome, measuring right eyes of 24 control and 13 Marfan syndrome subjects. Area under the receiver operating characteristic (AUROC) curve was assessed in univariate and multivariate analyses.<br />Results: Six investigator-derived ORA variables successfully discriminated Marfan syndrome. The best lone disease predictor was Concavity Min (Marfan syndrome 47.5 ± 20, control 69 ± 14, P = .003; AUROC = 0.80). Corneal hysteresis (CH) and corneal resistance factor (CRF) were decreased (Marfan syndrome CH 9.45 ± 1.62, control CH 11.24 ± 1.21, P = .01; Marfan syndrome CRF 9.77 ± 1.65, control CRF 11.03 ± 1.72, P = .01) and corneas were flatter in Marfan syndrome (Marfan syndrome Kmean 41.25 ± 2.09 diopter, control Kmean 42.70 ± 1.81 diopter, P = .046). No significant differences were observed in central corneal thickness, axial eye length, or intraocular pressure. A multivariate regression model incorporating corneal curvature and hysteresis loop area (HLA) provided the best predictive value for Marfan syndrome (AUROC = 0.85).<br />Conclusions: This study describes novel biodynamic features of corneal deformation responses in Marfan syndrome, including increased deformation, decreased bending resistance, and decreased energy dissipation capacity. A predictive model incorporating HLA and corneal curvature shows greatest potential for noninvasive clinical diagnosis of Marfan syndrome.<br /> (Copyright © 2016 Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
1879-1891
Volume :
161
Database :
MEDLINE
Journal :
American journal of ophthalmology
Publication Type :
Academic Journal
Accession number :
26432567
Full Text :
https://doi.org/10.1016/j.ajo.2015.09.027