Back to Search Start Over

Clotting factor product administration and same-day occurrence of thrombotic events, as recorded in a large healthcare database during 2008-2013.

Authors :
Ekezue BF
Sridhar G
Ovanesov MV
Forshee RA
Izurieta HS
Selvam N
Parunov LA
Jain N
Mintz PD
Epstein JS
Anderson SA
Menis MD
Source :
Journal of thrombosis and haemostasis : JTH [J Thromb Haemost] 2015 Dec; Vol. 13 (12), pp. 2168-79. Date of Electronic Publication: 2015 Nov 25.
Publication Year :
2015

Abstract

Background: Thrombotic events (TEs) are serious adverse events that can occur following administration of clotting factors (CFs).<br />Objectives: To evaluate occurrence of same-day TEs for different CF products and potential risk factors.<br />Methods: A retrospective cohort study of individuals exposed to CF products during 2008-2013 was conducted using a large commercial insurance database. CF products were identified by procedure codes, and TEs were ascertained via diagnosis codes. Crude same-day TE rates (per 1000 persons exposed) were estimated overall and by congenital factor deficiency (CFD) status, CF products, age and gender. Multivariable logistic regression analyses were used to control for confounding. Laboratory analysis was used to compare the procoagulant activities of FIX products.<br />Results: Of 3801 individuals exposed to CFs, 117 (30.8 per 1000) had same-day TEs recorded. The crude same-day TE rate was higher for CF users without CFD, 70.2 (102 of 1452), as compared with those with CFD, 6.4 (15 of 2349) (RR, 11.0; 95% CI, 6.4-18.9). For individuals without CFD, a significantly increased same-day TE risk was identified for factor IX complex (OR, 6.92; 95% CI, 3.11-15.40), factor VIIa (OR, 9.42; 95% CI, 4.99-17.78) and other products when compared with fibrin sealant. An increased risk of a TE was found with older age (≥ 45 years), history of TEs and underlying health conditions. The laboratory identified elevated procoagulant activity in Profilnine(®) and Benefix(®) .<br />Conclusions: The study shows an increased same-day TE risk for CF users without CFD and suggests substantial off-label CF use. The study findings also show elevated same-day TE rates for different CF products and suggest the importance of product properties and patient factors.<br /> (© 2015 International Society on Thrombosis and Haemostasis.)

Details

Language :
English
ISSN :
1538-7836
Volume :
13
Issue :
12
Database :
MEDLINE
Journal :
Journal of thrombosis and haemostasis : JTH
Publication Type :
Academic Journal
Accession number :
26414338
Full Text :
https://doi.org/10.1111/jth.13155