Back to Search Start Over

Cross-cultural adaptation and validation of the Nijmegen Cochlear Implant Questionnaire into Italian.

Authors :
Ottaviani F
Iacona E
Sykopetrites V
Schindler A
Mozzanica F
Source :
European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery [Eur Arch Otorhinolaryngol] 2016 Aug; Vol. 273 (8), pp. 2001-7. Date of Electronic Publication: 2015 Sep 01.
Publication Year :
2016

Abstract

The NCIQ is a quantifiable self-assessment health-related quality of life instrument specific for cochlear implant users. The aim of this study was to culturally adapt the NCIQ into Italian (I-NCIQ). A prospective instrument validation study was conducted. Cross-cultural adaptation and validation were accomplished. Cronbach α was used to test internal consistency in 51 CI users and in a control group composed by 38 post-lingual deaf adult on a waiting list for a CI. ICC test was used for test-retest reliability analysis. Kruskal-Wallis test with Mann-Whitney post hoc were used to compare the I-NCIQ scores in CI users before and after the cochlear implantation and in control patients. I-NCIQ scores obtained in CI users were compared with the results of Italian version of disyllabic testing without lip-reading and without masking. Good internal consistency and good test-retest reliability were found. I-NCIQ scores obtained in the 51 CI users after implantation were consistently higher than those obtained before implantation and in the control group. Moreover, no differences were found in the results of I-NCIQ obtained in the group of 51 CI users before implantation and in the group of control patients on post hoc Mann-Whitney analysis. Positive correlations between I-NCIQ scores and the results of disyllabic testing without lip-reading and without masking were found. The I-NCIQ is a reliable, valid, self-administered questionnaire for the measurement of QOL in CI users; its application is recommended.

Details

Language :
English
ISSN :
1434-4726
Volume :
273
Issue :
8
Database :
MEDLINE
Journal :
European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery
Publication Type :
Academic Journal
Accession number :
26324881
Full Text :
https://doi.org/10.1007/s00405-015-3765-8