Experimental Execution of the Simulated Pivot-Shift Test: A Systematic Review of Techniques.
- Source :
-
Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association [Arthroscopy] 2015 Dec; Vol. 31 (12), pp. 2445-54.e2. Date of Electronic Publication: 2015 Aug 28. - Publication Year :
- 2015
-
Abstract
- Purpose: To conduct a systematic review to identify and summarize the various techniques that have been used to simulate the pivot-shift test in vitro.<br />Methods: Medline, Embase, and the Cochrane Library were screened for studies involving the simulated pivot-shift test in human cadaveric knees published between 1946 and May 2014. Study parameters including sample size, study location, simulated pivot-shift technique, loads applied, knee flexion angles at which simulated pivot shift was tested, and kinematic evaluation tools were extracted and analyzed.<br />Results: Forty-eight studies reporting simulated pivot-shift testing on 627 cadaveric knees fulfilled the criteria. Reviewer inter-rater agreement for study selection showed a κ score of 0.960 (full-text review). Twenty-seven studies described the use of internal rotation torque, with a mean of 5.3 Nm (range, 1 to 18 Nm). Forty-seven studies described the use of valgus torque, with a mean of 8.8 Nm (range, 1 to 25 Nm). Four studies described the use of iliotibial tract tension, ranging from 10 to 88 N. Regarding static simulated pivot-shift test techniques, 100% of the studies performed testing at 30° of knee flexion, and the most tested range of motion in the continuous tests was 0° to 90°. Anterior tibial translation was the most analyzed parameter during the simulated pivot-shift test, being used in 45 studies. In 22% of the studies, a robotic system was used to simulate the pivot-shift test. Robotic systems were shown to have better control of the loading system and higher tracking system accuracy.<br />Conclusions: This study provides a reference for investigators who desire to apply simulated pivot shift in their in vitro studies. It is recommended to simulate the pivot-shift test using a 10-Nm valgus torque and 5-Nm internal rotation torque. Knee flexion of 30° is mandatory for testing.<br />Level of Evidence: Level IV, systematic review of basic science studies.<br /> (Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.)
Details
- Language :
- English
- ISSN :
- 1526-3231
- Volume :
- 31
- Issue :
- 12
- Database :
- MEDLINE
- Journal :
- Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association
- Publication Type :
- Academic Journal
- Accession number :
- 26321110
- Full Text :
- https://doi.org/10.1016/j.arthro.2015.06.027