Back to Search Start Over

Investigating the cytotoxicity of iron oxide nanoparticles in in vivo and in vitro studies.

Authors :
Ghasempour S
Shokrgozar MA
Ghasempour R
Alipour M
Source :
Experimental and toxicologic pathology : official journal of the Gesellschaft fur Toxikologische Pathologie [Exp Toxicol Pathol] 2015 Oct; Vol. 67 (10), pp. 509-15. Date of Electronic Publication: 2015 Aug 14.
Publication Year :
2015

Abstract

In recent years, iron oxide nanorods find a lot of applications including drug delivery, cell separation, hyperthermia and magnetic resonance imaging. In this study the cytotoxicity of iron oxide nanorods was evaluated based on mouse fibroblast cell behavior and wistar rat's liver and kidney function. At first for modification, nanorods were added to Dulbecco's modified Eagle's medium (DMEM) which contained a lot of sources of vitamins, amino acids, proteins in Fetal Bovine Serum (FBS). The MTT assay was employed for evaluating the toxic effects of 200 and 400 μg/mL modified and non-modified iron oxide nanorods on L929 mouse fibroblast cells in a 24h period. Changes in cell granularity and size as well as cell cycle were investigated using flow cytometry. Moreover liver and kidney function test and serum iron level measurement were performed 24h after the injection of modified iron oxide nanorods via the tail peripheral vein of wistar rats. Results indicated that greater concentration of modified iron oxide nanorods had no significant effect on cell viability while greater concentration of non-modified iron oxide nanorods significantly decreased cell viability. Modified iron oxide nanorods did not have significant effects on cell cycle. The results of liver and kidney function tests did not differ significantly while a significant increase in serum iron level was observed. After H&E staining of slices, there were no changes on morphology of rat's kidney and liver cells. This study suggests that short-time use of 200 and 400 μg/mL iron oxide nanorods are probably safe. Further studies are needed for investigation of toxic effects of different concentrations, coatings, and exposure time periods of iron oxide nanorods.<br /> (Copyright © 2015 Elsevier GmbH. All rights reserved.)

Details

Language :
English
ISSN :
1618-1433
Volume :
67
Issue :
10
Database :
MEDLINE
Journal :
Experimental and toxicologic pathology : official journal of the Gesellschaft fur Toxikologische Pathologie
Publication Type :
Academic Journal
Accession number :
26279467
Full Text :
https://doi.org/10.1016/j.etp.2015.07.005