Banding for type IA endoleak after endovascular abdominal aortic repair: An underexposed treatment option.

Authors :
van Lammeren GW
Ünlü Ç
De Vries JP
Source :
Vascular [Vascular] 2016 Apr; Vol. 24 (2), pp. 200-2. Date of Electronic Publication: 2015 Aug 05.
Publication Year :
2016

Abstract

More challenging abdominal aortic aneurysms with unfavorable proximal aortic neck anatomy are treated with endovascular means. As a consequence, proximal inadequate sealing may result in type IA endoleak, which in turn can lead to abdominal aortic aneurysm progression or rupture. The presence of type IA endoleak is an indication for secondary interventions. External aortic banding can be a good option to solve a type IA endoleak, but is underreported in literature; we present two cases and review literature.<br /> (© The Author(s) 2015.)