Back to Search Start Over

Simultaneous determination of ten compounds in rat plasma by UPLC-MS/MS: Application in the pharmacokinetic study of Ma-Zi-Ren-Wan.

Authors :
Hu DD
Han QB
Zhong LL
Li YH
Lin CY
Ho HM
Zhang M
Lin SH
Zhao L
Huang T
Mi H
Tan HS
Xu HX
Bian ZX
Source :
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences [J Chromatogr B Analyt Technol Biomed Life Sci] 2015 Sep 01; Vol. 1000, pp. 136-46. Date of Electronic Publication: 2015 Jul 14.
Publication Year :
2015

Abstract

Ma-Zi-Ren-Wan (MZRW) is a classic Chinese formula which has been used to treat human constipation in China for over 2000 years. In order to make good and rational use of this formula in the future, this paper presents the first attempt to track the pharmacokinetic features of MZRW in rat using rapid and sensitive ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). Ten chemical components of MZRW, namely, rhein, emodin, aloe emodin, hesperidin, naringin, amygdalin, albiflorin, paeoniflorin, magnolol and honokiol, were simultaneously determined in rat plasma after a single oral administration (10g/kg body weight) of MZRW to rats. Geniposide and liquiritin were used as internal standards. The separation was performed on a Waters ACQUITY BEH C18 column (100mm×2.1mm, 1.7μm). The detection was conducted by multiple-reaction monitoring (MRM) in negative ionization mode. Two highest abundant MRM transitions without interference were optimized for each analyte. This method was well validated in terms of linearity, precision, accuracy, recovery, matrix effect and stability. All calibration curves had good linearity (r(2)>0.995) over the concentration range from 3.9 to 125.0ng/mL for emodin, 3.9-500.0ng/mL for amygdalin, 2.0-4000.0ng/mL for naringin and hesperidin, 3.9-2000.0ng/mL for magnolol, 7.8-2000.0ng/mL for rhein and 3.9-4000.0ng/mL for albiflorin, paeoniflorin, aloe emodin and honokiol. The intra-day and inter-day precision (relative standard deviation) was within 15%, the accuracy (relative error) ranged from -13.6% to 15.1%, and the lower limit of quantification in plasma ranged between 2.0ng/mL and 7.8ng/mL. Extraction recovery, matrix effect and stability were satisfactory. The validated method was successfully applied to a pharmacokinetic study of these ten compounds after oral administration of MZRW to rats. The pharmacokinetic parameters of each compound can facilitate clinical studies in the future.<br /> (Copyright © 2015 Elsevier B.V. All rights reserved.)

Details

Language :
English
ISSN :
1873-376X
Volume :
1000
Database :
MEDLINE
Journal :
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences
Publication Type :
Academic Journal
Accession number :
26231677
Full Text :
https://doi.org/10.1016/j.jchromb.2015.07.003