Back to Search Start Over

Diffusion-weighted MR imaging using FASE sequence for 3T MR system: Preliminary comparison of capability for N-stage assessment by means of diffusion-weighted MR imaging using EPI sequence, STIR FASE imaging and FDG PET/CT for non-small cell lung cancer patients.

Authors :
Ohno Y
Koyama H
Yoshikawa T
Takenaka D
Kassai Y
Yui M
Matsumoto S
Sugimura K
Source :
European journal of radiology [Eur J Radiol] 2015 Nov; Vol. 84 (11), pp. 2321-31. Date of Electronic Publication: 2015 Jul 26.
Publication Year :
2015

Abstract

Purpose: To prospectively compare the diagnostic capability of diffusion-weighted MR imaging obtained with fast advantage spin-echo sequence (FASE-DWI) and echo planar imaging sequence (EPI-DWI), short inversion time inversion recovery fast advanced spin-echo (STIR FASE) imaging and FDG PET/CT for N-stage assessment of non-small cell carcinoma (NSCLC) patients.<br />Materials and Methods: 95 consecutive operable NSCLC patients underwent STIR FASE imaging, FASE-DWI and EPI-DWI with a 3T system, integrated PET/CT, surgical treatment and pathological and follow-up examinations. Probability of lymph node metastasis was visually assessed using a 5-point visual scoring system. ROC analyses were used to compare diagnostic capability of all methods, while their diagnostic performance was also compared by means of McNemar's test on a per node basis. Finally, McNemar's test was also used for statistical comparison of accuracy of N-stage assessment.<br />Results: Areas under the curve (Azs) for STIR FASE imaging (Az=0.95) and FASE-DWI (Az=0.92) were significantly larger than those for EPI-DWI (Az=0.78; p<0.0001 for STIR FSE imaging and FASE-DWI) and PET/CT (Az=0.85; p=0.0001 for STIR FSE imaging, p=0.03 for FASE-DWI) on a per node basis analysis. Accuracy of N-stage assessment using STIR FASE imaging (84.2% [80/95]) and FASE-DWI (83.2% [79/95]) was significantly higher than that using EPI-DWI (76.8% [73/95]; p=0.02 for STIR FASE imaging, p=0.03 for FASE-DWI) and PET/CT (73.7% [70/95]; p=0.002 for STIR FSE imaging, p=0.004 for FASE-DWI).<br />Conclusion: Qualitative N-stage assessments of NSCLC patients obtained with FASE-DWI as well as STIR FASE imaging are more sensitive and/or accurate than those obtained with EPI-DWI and FDG PET/CT.<br /> (Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.)

Details

Language :
English
ISSN :
1872-7727
Volume :
84
Issue :
11
Database :
MEDLINE
Journal :
European journal of radiology
Publication Type :
Academic Journal
Accession number :
26231045
Full Text :
https://doi.org/10.1016/j.ejrad.2015.07.019